Safe use rules
The safe use of Industrial Intrinsically safe EX handheld terminal EX PDA500i is based
on the user's compliance with the following rules of use.
a)
The battery provided by the mobile phone is a battery specially produced by the
manufacturer, and only the original battery meets the intrinsic safety requirements.Any
other non-original battery will cause the explosion-proof performance of the phone to
fail. So be sure to use the original battery. If you need to replace the battery, please
contact Beijing Delan.Battery is
Ex Battery 010 6000mAh
Explosion-proof polymer
battery.
b)
Charging the phone battery must be done in a safe area. And you must use the
original charger. The maximum charging voltage is 4.3V.
c)
It is forbidden to replace batteries for mobile phones in explosion hazardous
locations.
d) It is forbidden to be used in zone 0 of dangerous explosion places.
e)
It is forbidden to use earphones, data cables and other plug-in devices and Use
flash functionin explosion hazardous locations.
f)
It is forbidden to use the mobile phone vibration function in explosion hazardous
locations
.
g)
Keep away from high temperatures when using the phone.
Failure and damage handling
Any factor causing the phone may lose its intrinsic safety performance,please stop
using it in a dangerous place. It is recommended to send the phone back to the
manufacturer for testing
Conditions that may cause the explosion-proof performance of mobile phones to fail
include the following:
The phone case is damaged;
the explosion-proof mark cannot be identified;
Stored in areas that do not meet storage conditions; damaged in transit;
Other functions fail.