background image

DORMA

ED 200 ESR

WN 056461  45532

   06/12

Option: Locking device

The door is locked in closed position. When the

operator is activated, the door unlocks and moves

the door leaf to open position (fixed unlocking

period)

Option: Motorlock SVP 2xxx

(only possible with control unit B).

The door is locked in closed position. When the

operator is activated, the motor lock unlocks and the

operator opens the door.

Completion of installation

Connect earthing cable.

Install cover and fix with two screws.

Fix DORMA and ED 200 labels.

Pay attention to protect the secondary
closing edges during installation.

Briefing

After commissioning and adjustment of the operator

and accessories, the operating instructions must be

handed to the owner/user and the owner/user has to

be properly familiarised with the system.

   0

8

28

Subject to change without notice

Summary of Contents for ED 200 ESR

Page 1: ...hutzmaßnahme ausreichend Die Haupt und Nebenschließkanten müssen zusätzlich abgesichert werden Schutzflügel Sensoren Zur Einhaltung der Vorschrift müssen die statische Kraftbegrenzung die Schleichfahrtstrecken und die Geschwindigkeiten in Abhängigkeit zum Türflügel gewicht eingestellt werden Die dynamischen Kräfte müssen vor Ort mit einem Kraftmessgerät geprüft und die Einstellungen ggf geändert w...

Page 2: ...l schieben Endstücken auf Gleitschiene stecken Ventile 3 und 4 öffnen Gleitschiene am Türblatt befestigen 11c 12c 11b 8a 12a 8c 9c 10c 11a 9a 8b 9b 10b 13 16 17 15 14 18 10a 12b Montage Gleitschiene Bandseite Markierung auf Hebelauge L Hebelauge für DIN links Türen R Hebelauge für DIN rechts Türen Hebelauge in Hebel einsetzen Stellung des Vierkants zum Hebel beachten Hebelauge mit einem Hammer und...

Page 3: ...ereich wieder frei nimmt der Antrieb seinen normalen Betrieb wieder auf Bandgegenseite Befindet sich ein Hindernis im Erfassungsbereich der IRS Sicherheitsleiste reversiert die Tür bei der Schließfahrt bleibt die Tür in geöffneter Position stehen Ist der Überwachungsbereich wieder frei nimmt der Antrieb seinen normalen Betrieb wieder auf Steuerung B schaltet die Sensorleiste nach 5 Sek ab Sie ist ...

Page 4: ...it Steuerung B Die Tür ist im geschlossenen Zustand verriegelt Bei jeder Aktivierung eines Öffnungsimpulsgebers wird das Motorschloss entriegelt und die Tür öffnet Restmontage Schutzleiterkabel aufstecken Abdeckhaube aufsetzen und anschrauben Firmen Logo anbringen Bei der Montage ist auf die Absicherung der Nebenschließkante zu achten Einweisung Nach erfolgter Einstellung Inbetriebnahme der Türanl...

Page 5: ... the secondary closing edges have to be protected by further safety equipment Safety screens sensors In order to comply with this standard the static force limitation the driving phase for the low creep speed cycles and the speed have to be adjusted according to the door leaf weight The dynamic forces have to be checked on site with the aid of a dynamometer or similar and the respective settings h...

Page 6: ...slide channel Dimensional drawing Installation on pull side hinge side with slide channel Standard setting on delivery is for right handed DIN R ISO 5 CW closing doors To fit the operator to a left handed door the microswitch and the cam must be refitted on the other end of the axle Pull out the plastic nut and unscrew the end cap In the case the complete system can be installed direct attach it t...

Page 7: ...urn the cam with the pin supplied until the microswitch is activated Ensure that the position of the black cam remains unchanged Note As the door opens to this point the hinge side IRS sensor ceases to operate so that the door is not tripped by obstacles in the blanked range Ensure that the white cam once adjusted does not also activate the limit switch in the Door Closed position Sensors in accor...

Page 8: ...n the operator is activated the motor lock unlocks and the operator opens the door Completion of installation Connect earthing cable Install cover and fix with two screws Fix DORMA and ED 200 labels Pay attention to protect the secondary closing edges during installation Briefing After commissioning and adjustment of the operator and accessories the operating instructions must be handed to the own...