Commissioning
Technical Manual
55
04043552 - 07/2017
Terminal 97 00
6.2
Automatic registration via B-COMM
Start-up of the terminal takes place largely automatically in connection with the communica-
tion software B-COMM.
The device is preset at the factory for automatic registration via B-COMM.
For communication via WLAN, the connection must have been previously set up and activ-
ated. This is done via the system settings.
System requirements
•
B-COMM communication software version 4.0 and higher.
•
Network with a working DHCP server.
Start-up procedure
1.
Connect the power supply for the device.
ð
After booting, the device cyclically reports to the B-COMMs active in the network.
ð
At this point, until start-up by a
B-COMM is complete, the message
‘Waiting for registration’
is displayed on the dis-
play.
ð
Once the device is detected by B-COMM, the relevant data that identifies the device
will be queried.
ð
If the device is not known, it will be entered in B-COMM under the
B-COMM Terminal Discovery client under BCTDS (Terminal Discovery Stream).
2.
Add device in B-COMM to the desired communication channel.
3.
Provide device with the appropriate communication parameters.
ð
After having assigned the device permanently to B-COMM, B-COMM first updates
the settings of the device and then makes a backup of the settings together with the
'sop.ini’ licence file.
ð
The device now reports to the B-COMMs active in the network that registration has
been carried out, after which the device will be removed again from the BCTDS
stream by the other B-COMMS.
4.
Load specific parameters and master records to the device.
ð
The terminal software is restarted automatically. After that, the device is ready-to-oper-
ate.
6.2.1
Cancelling automatic registration
Automatic registration via B-COMM can be cancelled, in order to perform settings, for ex-
ample, manually.
ü
The device is waiting for registration by B-COMM. The message ‘
Waiting for registration
’
is shown on the display.
1.
Touch the Back icon in the navigation bar.
2.
Confirm cancellation.
ð
Cancellation takes place after no more than 10 seconds, followed by starting the terminal
software.