21
ED50/ED100/ED250
09-2021
DL4617-003
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Chapter 9
SAFETY
INFORMATION
Automatic Swinging Doors
1. Walk toward the door at a
normal pace. The door
should open when you are
about 4 feet from the door.
2. Stand motionless on
threshold for at least 10
seconds. The door should
not close.
3. Move clear of the area. The
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
4. Repeat steps 1 through 3
from other direction if door
is used for two way traffic.
5. Inspect the floor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
traffic path clear.
6. Inspect door's overall
condition. The appropriate
signage should be present.
7. Have door inspected by an
AAADM certified inspector
at least annually.
AAADM
American Association of Automatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualified automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks,
in addition to those in the
Owner’s Manual, should be
made each day and after any
loss of electrical power
.
9.8 Safety label, automatic swing
doors
9.8.1 Automatic swinging door safety information
label
This AAADM label outlines safety checks that should be
performed daily on automatic swinging door controlled
by an ED100 or ED250 operator configured for full
energy mode.
9.8.2 Safety information label location
Place label in a protected, visible location on door frame,
near program switch panel if possible.
9.8.3 Annual compliance section of label
This section of label is only completed on automatic
swing doors that comply with ANSI/BHMA A156.10
standard and pass inspection by an AAADM certified
dormakaba USA, Inc. technician.
9.8.4 Additional annual compliance inspection labels
Place additional labels over annual compliance
inspection section of safety information label.
SAFETY
INFORMATION
Low Energy Swinging
Doors
1. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4. Inspect the floor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
traffic path clear.
5. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6. Have door inspected by an
AAADM certified inspector
at least annually.
AAADM
American Association of Automatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualified automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks,
in addition to those in the
Owner’s Manual, should be
made each day and after any
loss of electrical power
.
Fig. 9.8.1 Safety information labels
9.9 Safety label, low energy swing
doors
9.9.1 Low energy swinging door safety information
label
This AAADM label outlines safety checks that should be
performed daily on low energy swinging door controlled
by an ED50 operator or an ED100/ED250 operator
configured for the low energy mode.
9.9.2 Safety information label location
Place label in a protected, visible location on door frame,
near program switch panel if possible.
9.9.3 Annual compliance section of label
This section of label is only completed on low energy
swing doors that comply with ANSI/BHMA A156.19
standard and pass inspection by an AAADM certified
dormakaba USA, Inc. technician.
9.9.4 Additional annual compliance inspection labels
Place additional labels over annual compliance
inspection section of safety information label.
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE: _____________
by AAADM Certified
Inspector
Number: ____________
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE: ______________
by AAADM Certified
Inspector
Number: ___________
Fig. 9.8.2 Annual compliance inspection labels