46
ED50/ED100/ED250
09-2021
DL4617-002
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Chapter 19
ED50/ED100/ED250 Parameter
A 156.19 standard
Parameter
Function
Factory
setting
Adjustment range
Para. Requirement
So
Opening time
Swing door openin, knowing
act switch.
25°/s
8°/s - 27/s
4.3
Opening
Doors shall open from closed to back check or
80°, whichever occurs first, in 3 seconds or
longer as required in Table I.
Total opening time to 90° shall be as in Table II
(next page) If door opens at more than 90°, it
shall continue at the same rate as backcheck
speed.
bc
Backcheck
Checking or slowing down of
door speed before door being
fully opened.
10°
5° - 40°
4.3
Backcheck shall not occur before 60° opening.
Sc
Closing speed
Swing door closing speed,
automatic mode.
19°/s
8°/s - 27/s
4.5
Closing
Doors shall close from 90° to 10° in 3 s or
longer as required in Table I (next page).
Doors shall close from 10° to fully closed in not
less than 1.5 s.
dd
Hold open
time
Hold open time
5 s
5 s - 30 s
4.4
Time delay
When powered open, the door shall remain
open at the fully opened position for not less
than 5 s.
Exception: when push-pull activation is used,
the door shall remain at the fully opened
position for not less than 3 s.
hS
Reference
Appendix A for
parameter
detail.
Support for manual mode in
door closed position.
4.6
Reference ANSI/BHMA A156.19, Para.
4.6, Force and Kinetic Energy.
hA
Adjustment, door activation
angle.
hF
Power assist function.
Fo
Static force
in opening
direction
Static force on door closing
edge in opening direction.
Parameter
setting *10
60 N
13.5 lb f
Parameter
setting *10
20 N - 60 N
4.5 lb f - 13.5 lb f
4.6
The force required to prevent a stopped door
from opening or closing shall not exceed
15 lb f [67 N] measured 1" from latch edge of
the door at any point during opening or closing.
Fc
Static force
in closing
direction
Static force on door closing
edge in closing direction.
Parameter
setting *10
60 N (*10)
13.5 lb f
Parameter
setting *10
20 N - 60 N (*10)
4.5 lb f - 13.5 lb f
4.6
19.2 Low energy power operated doors (ANSI/BHMA A156.19)
The following table references portions of content from ANSI/BHMA A156.19. Refer to the standard, available
through ANSI or BHMA for additional information. Standard material reprinted with BHMA permission
.
19.2.1 Door measurements, low energy power operated door.
Note 1: Speed may be slower after learning cycle
completed.