Setup and Troubleshooting Instructions
Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Night-bank hold open time
• Night-bank (key switch) hold open time is set using this parameter.
• Night-bank Hold open time starts once contact on night-bank activator input is
opened and door is in an open position; Night-bank hold open time can be re-triggered.
8
0 - 30
s
10
Hold open time, manual opening
• Default hold open time of 1 second that follows every manual opening of door can
be adjusted using parameter
do
.
• Hold open time starts when door is released.
9
0 - 30
s
1
Wall masking on door hinge side
• Wall masking required if door opens against an obstacle.
• When door reaches set wall masking angle, system will ignore signal from safety
sensor on door swing (hinge) side.
• The wider the detection range of safety sensor used, the greater the area must be in
which system has to ignore sensor's emitted signal. To insure personnel safety, it is
advised to keep this range as small as possible.
• If set wall masking angle is exceeded when door is being opened, a rapidly flashing
dot appears in top left hand corner of 2 digit display.
• Rapidly flashing dot disappears when door angle drops below set wall masking angle.
10
60
- 99
°
80
Safety sensor test
11
0 - 8
0
Safety sensor parameter
ST
must be set to sensors used and if they are active-
high or active-low. See E 04 safety sensor test error, Appendix B.
0
Sensor test off.
1
Sensor test on swing (hinge) side. Active-high
2
Sensor test on swing and approach sides. Active-high
3
Sensor test on swing and approach sides. Active-high
4
Sensor test on swing side. Active-low
ST
5
Sensor test on approach side. Active-low
6
Sensor test on swing and approach sides. Active-low
7
Wall mounted sensor with data line. Lock monitoring not available.
8
Sensor test overhead sensor type Bodyguard III or Premier T with monitoring
input.
Activation by safety sensor on approach
(opposite hinge) side
12
0 - 1
0
0
Safety sensor's input is disregarded as soon as door is closed.
1
Safety sensor can trigger an opening pulse while door is closed.
A.1.1 Driving parameters detail.