background image

Exit Device Operators 630/750/79E/RT/E7900 Series/ Generation E-730          PK3677_T 

10-18 

11

CAUTION

WARNING

IMPORTANT

If the lock will not respond to any keycard (includ-

ing the Emergency keycard), there are four options 

that should be attempted to open the door. In 

order, they are:
1.   Verify the batteries, and replace them if they 

are providing less than 4 Volts total. Use the 

Emergency keycard.

2.   Use the electronic override feature (requires 

FDU and communication cable or ATLAS 

M-Unit and IPM).

3.   Use mechanical key if locking system has one 

(see Section J, step 8). 

4.   Contact Technical Support for instructions on 

using the drill point. 

Electronic override using the FDU:

(For electronic override using ATLAS, please refer 

to ATLAS user guide) 

If the card reader fails, the E-730/630/750/79E 

lock can be opened using the FDU (Front Desk 

Unit). The lock must have been initialized by a 

valid FDU from the hotel where it is installed (i.e. 

with the correct internal and external hotel codes), 

before the electronic override can be used. 

There are two possible security levels:

Low security: IF an FDU with a software version 

lower than V2.01 overrides the lock, the lock audit 

records only the date and time.
High security: IF an FDU with version V2.01 or 

higher software overrides the lock, the lock audit 

records the FDU number, the Authorization key-

card number, the date and the time.

Hardware Required: 

Front Desk Unit (FDU) and Communication Cable

Minimum Authorization Keycard Required: 

Programming Authorization (PA)

G   Operating the emergency override

 

For RT lock series, 

please refer to system 6000 manual. For multihousing refer to RezShield manual.

S

teps to activate the E-730/630/750/79E 

electronic override:

1.  Insert the communication cable into the lock. 

Wait 2 seconds, then connect the cable to the 

serial port of the FDU.

CAUTION

WARNING

IMPORTANT

Some messages on the screen may differ depend-

ing on the FDU version, but the menu choices are 

the same.
2.  Press any key to activate the FDU, then swipe 

a PA or higher keycard through the FDU. If the 

green LED on the lock flashes once, disconnect 

the cable from the Serial Port, wait 2 seconds, 

and reconnect the cable.

Main Menu: 

1 = Keycard 

2 = Reset 

?

3.  Enter 8 to select the Programming Menu, then  

press < >. 

Program 

1 = A lock 

2 = Another FDU 

?

4.  Wait 2 seconds. Enter 1 to select the Lock 

option, and press < >. 

Enter Function 

1 = Program Addresses 

2 = Reset Addresses 

?

5.  Enter 7 to select the Override option, then  

press < >.

Ready to perform anelectrical 

override. 

Strike a key, or C to quit

6.  Wait 2 seconds, then press any key on the FDU 

to activate the electronic override. The green 

LED on the lock should light. The following mes-

sage should appear on the FDU screen immedi-

ately or within 2 seconds.

Trying to establish 

communication

Summary of Contents for 630 Series

Page 1: ...E 730 Series 630 Series 750 Series 79E RT E7900 Series Exit Device Operators 630 750 79E RT E7900 Series Generation E 730 Installation instructions PK3677 T 2018 09 EN ...

Page 2: ... Lock 9 G Operating the Emergency Override 10 H Test the operation of the 630 Lock 11 J Installing the Mechanical Override 12 Parts and Tools List 12 1 Upon unpacking the Lock 13 2 Preparing the Outside Housing for the Installation of the Lever 13 3 Preparing the Lever Handle and Cylinder for Installation 14 4 Steps to attach the Lever Handle to the Lock Housing 14 5 Attaching the Lever Handle to ...

Page 3: ...closure T 2 X Pan Head Screws 8 32 X 1 2 Tools Required Safety glasses 5 16 7 9mm drill bit 1 2 13mm drill bit 1 25mm drill bit Drill Awl or center punch Hammer Rubber mallet Small flat screwdriver Philips 2 screwdriver Spanner screwdriver No 6 1 8 Allen key Adjustable square Tape measure Pencil Tape Cleaning supplies drop cloth vacuum B A C D E F Q G H G J K E S COVER T S SUPPORT W W S SCREW Mech...

Page 4: ...ill the holes in the door required for the exit device according to the manufacturer s instructions CAUTION WARNING IMPORTANT Drill from both sides of the door to prevent unsightly damage Refer to template for drill size and depths 3 through holes From the inside counter bore 5 16 dia X 3 4 deep See Drilling Template 2 or 4 Holes Backset Vertical Line Inside of Door 3 4 Fig 1 Fig 2 B Introduction ...

Page 5: ... it For Mechanical Override Models refer to page 12 Assemble the lever on the outside housing in the horizontal rest position appropriate to the handing of the door as shown Simply push the lever onto the tube until it clicks in place If more force is required to engage the handle use a rubber mallet Test the attachment of the handle by pulling smartly on it For mortise exit devices install the mo...

Page 6: ...ce mechanism to jam the lock assembly once it is tightened down 4 2 Place the outside housing B on the door with gasket C if required 4 3 Attach Adaptor Plate E to the lock B using 3 Flat Head screw F 12 24nc 4 4 Attach the Exit Device chassis G to the Adaptor Plate E using 2 screws or 4 screws H depend ing on the Exit Device For Detex only use 2 or 4 Flat washers Q 4 5 Make sure the lock and the ...

Page 7: ...gasket C and the hole H3 For the hollow doors the wires shall pass inside the door to come out from the hole H2 5 3 Place the outside housing B on the door with gasket C if required 5 4 Attach adaptor plate E to the lock B using 3 flat head screw F 12 24unc for solid doors make sure that the wires are in the slot S1 5 5 Attach the Exit Device chassis G to the Adaptor Plate E using 2 screws or 4 sc...

Page 8: ...MOUNT VERTICALE ROD ANTENNA MODULE MESSENGER ANTENNA POSITION BLE ANTENNA POSITION ANTENNA MODULE EXIT DEVICE RIM MORTISE CONCEALED ROD MESSENGER ANTENNA POSITION BLE ANTENNA POSITION 5 Install Lock Exit Device with Messenger Bluetooth on the door continued D Install the lock and the exit device Continued ...

Page 9: ... For RT lock series please refer to system 6000 manual A Test the Lock Before Programming Normal Entry Use the Test keycard with the reader The red and green LEDs each flash once and then the green LED flashes for four seconds Turn the outside lever downward while the green LED is flashing The latch or rod retracts fully Release the lever then turn it again The latch or rod must not retract after ...

Page 10: ...ds remain cancelled in the new lock and will set the addresses for the Section Floor Group Zone and Area sub master level so that staff key cards in use at the property will have the same pattern of access to the door as before This step makes the lock replacement transparent so that the new lock accepts and rejects the same keycards as the old lock Multihousing Program the lock using the M unit o...

Page 11: ...k the lock audit records the FDU number the Authorization key card number the date and the time Hardware Required Front Desk Unit FDU and Communication Cable Minimum Authorization Keycard Required Programming Authorization PA G Operating the emergency overrideFor RT lock series please refer to system 6000 manual For multihousing refer to RezShield manual Steps to activate the E 730 630 750 79E ele...

Page 12: ...ight hard to turn or does not return easily to its horizontal rest position check the spindle length vs the door thickness the spindle may be too long Check that the slotted end of the spindle is inserted in the lock housing hub not the exit device 3 Electronic A Programming Program the lock with at least one user using the Oracode Maintenance Unit Generate a valid code for this user Recommendatio...

Page 13: ...el E Drive tube F Lever catch G Countersink H Lever handle I Cap J Cylinder K Cylinder plug L Override shaft K1 Set Screw Back A H E B D F I J K K1 E L F G C Front J Installation of the mechanical override Parts and Tools List Facing view of drive tube E Diagram of lock Tools Required U Cylinder provided with lock or equivalent T Small flat scewdriver less that 1 8 ...

Page 14: ... WARNING IMPORTANT Assemble the lever cylinder and lock compo nents before affixing the entire unit to the door A The small indents on the cross of the override shaft in line horizontally B The nylon washer and the spring washer not for lever feel on the drive tube C The lever catch in the out position D Cylinder and 2 keys for 630 K C included in the hardware bag 1 Upon unpacking the lock housing...

Page 15: ...er plug does not fall out insert the key into the cylinder The key will be horizontal See Fig 5 3 Preparing the Lever Handle and Cylinder for Installation 3 Insert the cylinder into the lever handle see Fig 3 4 Steps to attach the lever handle to the lock housing NOTE THE POSITION OF THE KEY IS VERY IMPORTANT CAUTION WARNING IMPORTANT The key and the countersink must be in the positions shown in F...

Page 16: ...ever handle with a cloth or other material to protect the finish of the metal 9 Remove the key The lock will look as shown in Fig 10 Gently check the rotation of the lever handle It should easily rotate approximately 45º Troubleshooting Right handed Lock Turn the lever handle clock wise without forcing it If it stops at approxi mately 15º it was not assembled correctly as shown in step 4 Fig 6 7 D...

Page 17: ...steps 2 3 4 5 and make sure that the lever looks like Fig 10 and repeat this verification process Step 6 Fig 11 CAUTION WARNING IMPORTANT This test can only be performed when the lock is not affixed to the door 16 Without using the key turn the lever han dle clockwise for Right handed locks or counter clockwise for Left handed locks The inside drive hub should not rotate when the handle turns Fig ...

Page 18: ... and counter clockwise for left handed locks The latch must retract 21 Extend deadbolt and repeat the above operation turn key clockwise until it stops latch and deadbolt must retract completely Fig 16 Fig 17 23a Loosen the set screw 01 to free the lever using Allen Key P1 Approx 1 4 turn 24 Remove the cap from the lever handle see step 23 Fig 16 25 Insert key 26 Turn the key clockwise until it st...

Page 19: ...lever Remove control key F 7 Insert the change key into the remov able core Follow the rest of instructions from step 3 5 of page 12 7 Pins Thinner Adapter 6 Pins Thicker Adapter 10 How to Change Lock Cylinders continued CAUTION WARNING IMPORTANT The Key Override itself does not retract the latch or deadbolt Do not use too much force when turning the key as this may damage the unit To retract the ...

Page 20: ...e the receiving antenna Increase the separation between the equip ment and receiver Consult the dealer or an experienced radio TV technician for help Statement according to FCC part 15 21 Modifications not expressly approved by dor makaba could void the user s authority to operate the equipment Statement according to FCC part 15 19 This device complies with part 15 of the FCC rules and Industry Ca...

Page 21: ...Exit Device Operators 630 750 79E RT E7900 Series Generation E 730 PK3677_T 10 18 21 ...

Page 22: ...omer Services Support Ilco 1 877 468 3555 1 514 340 9025 Saflok 1 800 999 6213 1 248 837 3700 General Information dormakaba us Online Consumable Orders www ilcostore com www saflokstore com To access all of our easy steps please visit our Support Website www kabalodgingsupport com ...

Reviews: