2
OFFICE locks
2018-05
WN 059521 45532
dormakaba Mounting instructions
Product description
• Never use clamping shoes on self-cleaning
coatings.
• When adjusting glass elements, always
stick to the required clearance for the
respective fitting. Adjust clearance so that
the glass does not touch hard
components such as glass, metal or
concrete.
2.3
Requirements for the glass
door panel
• Toughened safety glass (TSG)
• In areas with additional requirements, e.g.
nurseries, the use of heat-soaked
toughened safety glass (TSG-H compliant
with DIN EN 12150-1) is recommended.
• Do not use glass with conchoidal fractures
and/or damaged edges.
• Installation should be free of tension
(torque should not be exceeded by
over-tightening screws).
3
Product description
The OFFICE locks with latch and bolt are
suitable for glass doors in dry interior
applications. The locks comply with the
current DIN EN 12209 and are designed for
the use in public buildings. The profile
cylinder is not included in the scope of
delivery.
Fig. 1
Door situation
Fig. 2
DIN right
DIN left
DIN left
DIN right
DIN directions