background image

(P/N) 3118.0210 Rev C 06/18 • © copyright 2010-2018 

dormakaba USA Inc.

 

Page 1 of 4

INSTALLATION INSTRUCTIONS

The installation instructions are the basis for Security Agency Approvals. The lock installation must be done in accordance to 

these instructions in order to maintain the labeled approval level.

In order to maintain VdS Class 2/EN 1300 Class B lock approval levels in a container where multiple locks are required, special 

considerations must be observed. The Auditcon 2 Series lock must be the first one secured by the boltworks. Check the locked 

status of the container with the handle of the boltworks.

Design Parameters for Auditcon 2 Series Locks

1.  Bolt dimensions (nominal): .313 inches x .900 inches/7.95 x 22.8mm

2.  Bolt movement (nominal): .475 inches/12.07mm

3.  Bolt extension: .475 inches/12.07mm

4.  Maximum load movable by the bolt: None

NOTE: 

Auditcon 2 swing bolt locks must be installed in such a way that no side or counter acting load affects the bolt and the 

bolt can move freely.
5.  Maximum load against bolt when thrown (all directions): 224.8 lbs.(1kN) 

6.  The lock can be fitted to safes or vault doors of any material.

NOTE: 

As is the case with all mechanical and electronic locking devices, the container and boltworks must be designed to 

protect the lock.

AUDITCON

®

 2 SERIES LOCKS

MODELS 52, T52, 252, 552 - ROUND HOUSING SWING BOLT

Basic Tools and Materials Needed

•  Medium Phillips head screwdriver (#2) (recommend 

magnetized tip)

•  6/64" Allen Wrench

• ESD wrist band

Recommended, but not required:

•  Torque screwdriver (30 inch-pounds/3.4 newton-meters 

capacity)

• Loctite

®

 262 (Red) for use on lock case mounting screws

WARNING: dormakaba

 

locks are protected from 25,000 

V Electrostatic Discharge (ESD) damage when correctly 

installed. Follow these precautions to avoid ESD damage 

when installing the lock: 

• Handle the keypad assembly by the outer edge only. 

•  Use an ESD wrist band grounded to the lock or container 

during installation.

Dial Assembly

Lock Case

Assembly

Dial Assembly

Mounting

Screws (2)

Lock Case

Mounting

Screws (3)

Keypad Assembly

with Decal

Cable

Figure 1 - Swing Bolt Lock Parts

Figure 2 - Swing Bolt Clearances and Positioning

Summary of Contents for AUDITCON 2 Series

Page 1: ... and the bolt can move freely 5 Maximum load against bolt when thrown all directions 224 8 lbs 1kN 6 The lock can be fitted to safes or vault doors of any material NOTE As is the case with all mechanical and electronic locking devices the container and boltworks must be designed to protect the lock AUDITCON 2 SERIES LOCKS MODELS 52 T52 252 552 ROUND HOUSING SWING BOLT Basic Tools and Materials Nee...

Page 2: ... wrench Tighten the screws Torque 17 20 lbs 1 9 2 25 N M and then ensure that the dial turns smoothly Figure 6 6 Insert the 4 pin generator cable on the dial assembly into the 4 pin connector on the back of the keypad assembly The generator cable will only connect to the keypad assembly in one orientation Figure 7 7 Insert the keyed Picoflex connector on the end of the ribbon cable into the connec...

Page 3: ...he movement of the boltworks must however contact the bolt on the flat edge not on the rounded side of the bolt It is recommended that you use Loctite 262 Red on the lock case mounting screws 2 Test the operation of the lock again If the lock does not operate properly refer to the following instructions to Uninstall Keypad Assembly 3 If your lock includes the Battery Assist option you should now m...

Page 4: ...oes not represent a commitment on the part of dormakaba dormakaba shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material dormakaba USA Inc 749 W Short Street Lexington KY 40508 USA Phone 859 253 4744 FAX 859 255 2655 Technical Support 800 950 4744 Document Numb...