Maintenance
Technical Manual
121
V28 - 08/2019
Electronic safe lock
ð
After a few seconds the new lock will be placed automatically to the vacant lock posi-
tion -9-.
The display shows a warning that the battery compartment of the newly added lock
was opened.
4.
Enter a Battery Code to be able to operate the lock.
19.1.2.2
Adding a new lock with Freeze ON
The function Freeze is set to ON and the Lock info is set to OFF on lock -1- (master lock).
It is assumed that e.g. lock -9- was defect and the lock was removed from the safe lock sys-
tem. The safe lock systems indicates that lock position -9- is vacant.
A new lock will be added to lock position -9-.
Authorization: Master Code
Adding a new lock
1.
Add the new lock to the secure storage unit.
2.
Connect the bus cable from terminal X2 of the previous lock to terminal X1 of the newly
added lock.
3.
Connect the bus cable from terminal X2 of the newly added lock to terminal X1 of the sub-
sequent lock.
ð
After a few seconds the new lock will be assigned to position -16-.
The display shows a warning with an error message for the newly assigned lock.
4.
Press the LEFT or RIGHT arrow key as long as the error message with the lock position
-16- will be displayed.
Changing the function Freeze to OFF
1.
Open lock -1- and prevent the lock from closing.
2.
Enter the programming mode.
3.
Select the menu MISC.
4.
Press the ENTER key.
5.
Select the submenu FREEZE
6.
Press the ENTER key.
7.
Select OFF by using the LEFT or RIGHT arrow key.
8. Press the ENTER key to confirm the setting.
9.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
10. Press the ENTER key to confirm the setting.
11. Press the DEL key several times to exit the programming mode.