Functionality
Technical Manual
30
V28 - 08/2019
Electronic safe lock
11.3
Immediate Time Lock
The Immediate Time Lock is a useful function to bridge the time period until a regular locking
period of the electronic safe lock starts.
When the lock is closed, it is not possible to open it for the configured time period
The maximum time period is 144 hours.
Changing hours and minutes to 000:00 will deactivate the Immediate Time Lock.
By default it is possible for the Master to override the Immediate Time Lock.
It is possible to deactivate this function via AS284-USBW or AS284-NETW programming soft-
ware.
The Immediate Time Lock is not related to time/date.
It is not possible to bypass the Immediate Time Lock by changing the settings for time/date.
1.
If the display is in sleep mode, press any key to wake up the display.
ð
The lock status appears (for example "locked").
2.
Press the MODE key.
3.
Use the NUMERIC keys to enter a valid User Code (for example 12104453).
ð
For every entered digit an asterisk appears on the display.
4.
Press the ENTER key to confirm the code.
ð
The lock is in Programming Mode for the Immediate Time Lock.
5.
Press the ENTER key twice .
6.
Use the LEFT or RIGHT arrow key to set the duration of time in hours and minutes.
7.
Press the ENTER key.
8. Select "YES" by using the LEFT or RIGHT key.
9.
Press the ENTER key to confirm the settings.
10. Press the DEL key twice to exit the menu.
11.4
Time-Related Functions
The Time-Related Functions "Delay", "Toggle Dual Mode" and "Code Disabling" are only op-
erated in Bank Mode.
The functions are only configurable with Master Code either with the input unit or via AS284-
USBW or AS284-NETW programming software.
It is possible to select and configure individual settings (with up to 3 time windows and for any
weekly interval) for user groups 1, 2 and 3.
User group 1 comprises all users of group 1, 1 Manager of group 1 and the Master.
An activated Immediate Time Lock prevents the execution of the Time-Related Functions and
all related subfunctions.
Partial Locking is a subfunction of the Time-Related Functions only operated in Bank Mode.
An activated Partial Locking overrides the set Time-Related functions "Delay", "Toggle Dual
Mode" and "Code Disabling" for the selected user groups.
When the lock is opened in Bank Mode after Partial Locking had been reset, the function will
be activated again.
The following events reset Partial Locking: