Functionality
Technical Manual
31
V28 - 08/2019
Electronic safe lock
•
Immediate Time Locking
•
Time Locking (Weekly and Holiday Locking Periods)
•
Penalty
•
Remote Disabling
Reaching an endpoint of a Time-Related Function does not reset Partial Locking.
The state of the function "Partial Locking" (activated or reset) does not depend on the start-
ing or endpoint of a Time-Related Function.
If the state of the function "Partial Locking" (activated or reset) is set to an output, this out-
put switches on as soon as the lock will be opened.
The output is as long switched on as one of the events (Immediate Time Lock, Time Locking,
Penalty and Remote Disabling) will reset Partial Locking.
11.5
Beep signals
It is possible to deactivate the beep signal via AS284-USBW or AS284-NETW programming
software when the display shows "OPEN" (for open lock), "WAIT" (for Time Delay) and
"CONF" (for Confirmation Window).
It is also possible to set the beep signal volume to high/low or to deactivate it.
Type of beep signal
Duration
Display
Cause
1 short beep
Key stroke
1 short, low-fre-
quency beep
REFUSED
Action refused
1 short beep
Every 60 seconds
WAIT
Time Delay or Duress
Time Delay is activated.
3 short beeps
Every 60 seconds
CONF
The Confirmation Win-
dow is activated.
After the Time Delay is
over, it is possible to enter
the confirmation code.
10 short beeps
Every 10 seconds
BAT-CMP OPEN
The Battery Compart-
ment was opened.
10 short beeps
Every 10 seconds
OPEN
The lock is open.
11.6
Status messages
11.6.1
Bank Mode and One Time Mode
Bank Mode
•
Bank Mode is the factory setting and standard operating mode for all products.
•
In Bank Mode the unit runs standalone according to the configuration.
One Time Mode
•
One Time Mode (OTM) is the umbrella term for all interactive operations.
•
OTM comprises the functions: OTC, ICS, CIT and DM with ICS and OTC.
•
In OTM the electronic safe lock accepts a generated code from the dispatch center for
one single opening for an unlimited time period.