Functionality
Technical Manual
36
V28 - 08/2019
Electronic safe lock
It is possible to deny codes with a superior code.
These codes are declared invalid for a certain time period until these codes are permitted
again.
When identifying with a denied code, the status message DENIED will be displayed.
The selected function will not be executed, the lock condition remains unchanged.
The same status message will be displayed when trying to open the lock by using a Manager
or the Master Code which was set to "cannot open".
The status message DENIED will also be displayed as long as the set NRTD refuses to open
the lock.
In Mixed Mode it is possible to configure the safe lock via AS284-USBW or AS284-NETW pro-
gramming software so that a One Time Code is able to override NRTD.
Time-Related Functions (Bank Mode)
The number next to "TR-FNC" indicates the respective user group.
The number below "TR-FNC" indicates the number of the activated Time-Related Functions
of the respective user group.
The battery compartment was opened (Bank Mode and OTM)
The status message BAT-CMP is displayed if:
1
the lock is open while the battery compartment was opened
2
the lock is closed and the battery compartment was opened and closed again.
It is possible to delete the status message by entering a valid Manager, Master or Battery
Code (User Codes 41, 42 or 47).
In OTM a Battery Code is required.
Connection to a programming software (Bank Mode and OTM)
The input unit is not operative and all keys are deactivated when the lock is connected to a
computer via USB cable and data exchange with AS284-NETW programming software is in
progress.
@
The input unit is not operative and all keys are deactivated when the lock is connected to a
computer via LAN and data exchange with AS284-NETW programming software is in
progress.
The graphic only shows the @ icon and no other information.
External power supply available (Bank Mode and OTM)
A dot is shown on the display if an external power supply is available for the lock or the eBox.
This status message is updated every full hour.
The graphic only shows the dot icon and no other information.