Installation
Technical Manual
69
V28 - 08/2019
Electronic safe lock
X3 or X4
Connection to lock (it is only possible
to connect 1 lock to an eBox).
It does not matter if X3 or X4 is used.
Use the enclosed connecting cable.
RJ45
Connection to a LAN
10/100 Base T Ethernet
Min. CAT5 cable required.
Connecting network devices must
have a ground connection.
14.7
eBox wiring diagram
e
Bo
x
In
te
rn
a
l
C
ircu
it
In
p
u
ts
O
u
tp
u
ts
Power supply
OUT 3A ... 7A
OUT 3B ... 7B
IN 3 ... 7
GND
Load
14.8
Wiring
There are 2 options to set up a safe lock system:
–
Cold plugging
–
Hot plugging
The higher the number of used components and the bigger the distances between the compo-
nents, it is important to follow this rule:
–
To create a wiring loop if the distance between the components is rather high.
–
To connect either the eBox or the power supply with a maximum distance from the in-
put unit.
14.8.1
Cold plugging
When wiring a safe lock system neither put batteries in the battery compartment nor connect
an external power supply to the last position of the safe lock system. Do not power the eBox
either.
The following instruction describes the setting up of a standard safe lock system with all op-
tional devices (a second input unit, two eBoxes and an external power supply).
It is assumed that the locks have only factory settings.
The functions Freeze and Lock info are set to OFF on the master lock.
Connecting an input unit and locks
1.
Connect the connecting cable from the 6-pole connector terminal of the input unit to ter-
minal X1 of the first lock.