Configuration
Technical Manual
87
V28 - 08/2019
Electronic safe lock
If Manager Codes were defined via AS284-USBW or AS284-NETW programming software as
"Manager can change Confirmation Window", it is possible to change this setting with Man-
ager Codes.
Ex factory the Confirmation Window is set to 5 minutes.
The minimum value is 1 minute.
The maximum configurable value of a Time Delay must be shorter than the shortest time gap
between any 2 Weekly Locking Periods.
The set value for the Confirmation Window is also used for skipping a Time Delay with the
Courier Code, if the function "Courier Code does not open, but skips Time Delay" is activated.
It is not possible to deactivate the Confirmation Window.
1.
Select the submenu CNF WIN.
2.
Press the ENTER key.
ð
The currently set confirmation time will be displayed.
3.
Use the LEFT or RIGHT arrow key to set the defined confirmation time (setting from 1:00
to 99:00 minutes).
4.
Press the ENTER key.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the settings.
15.1.7.3
Configuring NRTD
Submenu NRTD-HM
Ex factory NRTD is set to 0 minutes.
It is possible to override NRTD with a code generated in OTM (AS274).
This function must be activated by AS284-USBW programming software.
When closing the lock, it is not possible to open the lock during the set duration for NRTD.
1.
Select the menu NRTD-HM.
2.
Press the ENTER key.
ð
The currently set NRTD will be displayed (hours:minutes).
3.
Use the LEFT or RIGHT arrow key to set the defined NRTD (setting from 00:00 min. to
99:00 h).
4.
Press the ENTER key.