Configuration
Technical Manual
94
V28 - 08/2019
Electronic safe lock
1.
Select the menu CODE.
2.
Press the ENTER key.
3.
Use the LEFT or RIGHT arrow key to select the code type (for example "user") to be
changed.
4.
Press the ENTER key.
5.
Use the LEFT or RIGHT arrow key to select the code (for example "User Code 11") to be
changed.
6.
Press the DEL key.
ð
The user is asked either to delete or not to delete the code.
7.
Select "YES" by using the LEFT or RIGHT arrow key.
8. Press the ENTER key to confirm the deletion.
15.1.8.7
Resetting the electronic safe lock
Submenu SHELVE
With the Shelve Function it is possible to reset the electronic safe lock to factory settings
(Bank Mode).
All codes will be deleted and all parameters such as Time Delay, Time Locking Function, Dual
Mode will be set to factory settings.
Time/date, opening counter and audit trail remain unchanged.
Keep in mind that all data is lost when the electronic safe lock will be reset to factory settings.
It is recommended to save all data via AS284-USBW or AS284-NETW programming software
prior to shelving.
Keep in mind that codes cannot be saved.
Authorization: Master Code
1.
Select the submenu SHELVE.
2.
Press the ENTER key.
ð
The user is asked either to reset or not to reset all data to factory settings.
3.
Select "YES" by using the LEFT or RIGHT arrow key.