Installation
Technical Manual
67
V28 - 08/2019
Electronic safe lock
1
2 3 4 5 6 7 8
X1
X2
Sockets
Description
Remarks
X1, X2
Connection for input unit or eBox or
connection for power supply
Use the enclosed connecting cable.
Only use the original Axessor power
supply.
14.5
Installing the eBox
As a requirement of EN 1300 the eBox must be installed inside the safe.
93.5
106.5
2
7
2
7
A
A
1.
Mark 2 fixation holes (A) according to the graphic.
2.
Drill fixation holes Ø5 mm.
3.
Remove the burrs.
4.
Install M6 threads in the fixation holes.
5.
Install the eBox with two M6x10 socket screws (it is also possible to use similar inch
screws instead).
14.6
External connections on the eBox
Do not power the eBox before starting the wiring procedure.
Requirements:
The eBox functions are only available if:
•
the eBox is connected to an Axessor lock
•
the eBox is connected to a power supply.
The eBox provides:
•
5 additional inputs and outputs
•
2 bus sockets
•
1 RJ45 socket.