10
Safe locks: Axessor series
dormakaba Quick reference guide
2018-03
0.0
Function
Factory setting
U
S
B
IP
C
IT
Change with
Input
unit
AS284-USBW
AS284-NETW
(optional)
Time delay in One Time Mode (OTM)
0 minutes
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Duress time delay in One Time Mode (OTM)
99 minutes
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Time delay and duress time delay
Count down
✓
✓
✓
✓ (IP)
✓ (CIT)
Non-return time delay in One Time Mode
(with CIT) and Bank mode (with IP & CIT)
0 minutes
N/A
✓
✓
✓ (IP)
✓ (CIT)
✓ (IP)
✓ (CIT)
OTM overrides non-related time delay
Off
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Bolt open time in Bank mode
6 seconds
✓
✓
✓
✓ (IP)
✓ (CIT)
✓
Bolt open time in One Time Mode (OTM)
2 minutes
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Process time
2 min. 30 sec.
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Wake up mode
CIT
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Confirmation window (CONF)
5 minutes
✓
✓
✓
✓
✓
Immediate time lock period
0 minutes
✓
✓
✓
✓
✓
Maximum adjustable value for immediate
time lock period
144 hours
✓
✓
✓
✓
Opening windows for time lock interruption
Off
N/A
✓
✓
✓ (IP)
✓ (CIT)
✓ (IP)
✓ (CIT)
Time lock functions also cover OTM
Off
N/A N/A ✓
✓ (CIT)
✓ (CIT)
Date
Time
01.01.2017
0:00
✓
✓
✓
✓
✓
Time format ( 24hours or 12hours AM/PM )
24 hours
✓
✓
✓
✓
✓
Change of summer / winter time (Daylight
Saving Time) and factory setting of time
zone
On to Central
European
Time
✓
✓
✓
✓
✓
Remote disabling by software
Off
✓
✓
✓
✓
✓
Input 1: one function optionally assignable
(remote disabling / controlled disabl. / remote
enabling / cancel non-return time delay)
Off
✓
✓
✓
✓
Input 2: one function optionally assignable
(door contact / skip time delay / time lock
interruption / remote disabling / controlled
disabling / external input event A – F / remote
enabling / cancel non-return time delay)
Off
✓
✓
✓
✓
Output 1: duress alarm
On
✓
✓
✓
✓
Output 2: lock open (OR boolean operation
with lock open or motor open or door open)
On
✓
✓
✓
✓
Factory settings / Part 3