4
Safe locks: Axessor series
dormakaba Quick reference guide
2018-03
Open Lock
Note
The overview shows the code structure of the Axessor series units.
Axessor USB safe locks are able to manage a maximum of 2 user groups.
Axessor CIT and Axessor IP safe locks are able to manage a maximum of
4 user groups.
Master code
0 0 x x x x x x
User group 1
(CIT & IP & USB)
Manager 1
1 0 x x x x x x
User 11
1 1 x x x x x x
:
User 19
1 9 x x x x x x
User group 2
(CIT & IP & USB)
Manager 2
2 0 x x x x x x
User 21
2 1 x x x x x x
:
User 29
2 9 x x x x x x
User group 3
(CIT & IP)
Manager 3
3 0 x x x x x x
User 31
3 1 x x x x x x
:
User 39
3 9 x x x x x x
User group 4
(CIT & IP)
Manager 4
4 0 x x x x x x
User 41
4 1 x x x x x x
:
User 49
4 9 x x x x x x
Courier code
9 0 x x x x x x
Duress code
Enter the Duress code by adding or deducting the value 1 to or from the last digit
of the User, Manager or Master code.
Code structure and basic operation of Axessor units
Note
When Input 2 of the Axessor safe lock is not configured as "door contact",
the bolt will automatically close after the "Bolt open time in Bank mode"
or the "Bolt open time in One time mode (OTM)" has elapsed.
Enter a valid code
and press
Lock is closed
Lock is open
Note
Precondition to recognize a Duress code: Duress function must be
activated. Axessor IP and CIT units accept any value of +/- 1...9 as Duress
code.