Maintenance
Technical Manual
55
HAC Standard fixing - 02/2018
dormakaba c-lever pro
7 Maintenance
This section describes product maintenance.
7.1
Maintenance table
The component's mechanism and/or electronics do not require any maintenance.
NOTICE
Opening the mechatronic unit.
Opening the mechatronic unit releases the manufacturer from any liability under the guaran-
tee.
Components
Measures
Interval
All components
Function check in accordance with instruc-
tions
12 months
Replacing the batteries
24 months
1
Clock (components)
Check and set clock time with the system
software
12 months
Firmware update
To modify functionality
See the system description
as required
Key:
1
With lithium batteries
7.2
Cleaning
Only disinfection agents that are explicitly formulated for cleaning delicate metal surfaces
and plastics may be used. The use of unsuitable cleaning agents or methods can damage the
components' surface.
1.