13
Crane 4000LE
07-2022
RL6002-003
Chapter 4
Crane 4000LE Wiring, Setup and Troubleshooting Manual
In-ground Motion Assist 360 drive and speed control
Remote control enclosure
4.5 Wave to Open plate (option)
4.5.1 Wave to Open plate.
Locations:
• Inside the building on the leading quarter post/end
wall or attached separately within sight of the
revolving door.
• Building
exterior.
Plate starts rotary movement of the door wings at low
energy speed (Para. 4.2.4).
CAUTION
Plates must be located per
ANSI BHMA A156.27, Power and manually
Operated Revolving Pedestrian Doors.
TIPS AND RECOMMENDATIONS
Plates only used with "S" (green) function module,
Para. 2.7.
Fig. 4.5.1 Wave to Open
plate
DX3331-001
Fig. 4.5.2 Wave to Open
plate
DX3339-189