24
Crane 4000LE
07-2022
RL6002-003
Chapter 6
Crane 4000LE Wiring, Setup and Troubleshooting Manual
In-ground Motion Assist 360 drive and speed control
Remote control enclosure
6.10 Connect 115 Vac and earth ground cable from remote enclosure to
customer 115 Vac distribution panel
Fig. 6.10.2
Detail "A":
Fig. 6.10.1 Remote enclosure DC cables and 115 Vac wiring
6.10.1 Connect 14 AWG earth ground cable from
remote enclosure to customer distribution panel
ground.
1. Connect one end of earth ground cable to Motion
Assist 360 power supply fastener as shown in
Fig. 6.10.2.
2. Route earth ground wire from remote enclosure to
customer distribution panel.
3. Connect earth ground wire to ground.
6.10.2 Connect 115 Vac from customer distribution
panel to Motion Assist 360 power supply
115 Vac plug.
CAUTION
Customer 115 Vac circuit breaker must be OFF!
1. Connect 115 Vac wiring to Motion Assist 360 power
supply 115 Vac plug as shown in Fig. 6.10.4
WARNING
Work on electrical equipment and 115 Vac
wiring installation must be performed only by
qualified personnel
!
Fig. 6.10.3
Motion Assist 360 power supply
Fig. 6.10.4
Inlet socket AC plug, customer 115 Vac
#
Description
1
RX6001
Motion Assist 360 power supply
1.1
Plug for customer 115 Vac wiring
1.2
115 Vac cable to control unit
2
RX6002
Motion Assist 360 control unit
3
RX6016-001
Motor extension cable, 25' (standard)
4
RX6015-001
Hall sensor extension cable, 25' (standard)
5
Earth ground wire to in-ground container
7
Customer 115 Vac
7.1
Customer earth ground wire
8
RF6018-01G
5/16 x 1/2" SHCS, SS
9
RF6019-01G
5/16" flat washer
10
RF6016-01G
External tooth lock washer
Table 6.10.1 Remote enclosure hardware and wiring
10
7.1
5
8
9
1
1.1
1.2
N
L
1.1
7
7
L
N
1”
1/4”
7
DC wiring
conduit
115 Vac conduit
7
7.1
1
2
3
4
5
Enclosure
ground wire
5