26
Crane 4000LE
07-2022
RL6002-003
Chapter 6
Crane 4000LE Wiring, Setup and Troubleshooting Manual
In-ground Motion Assist 360 drive and speed control
Remote control enclosure
6.12 Connect Motion Assist 360 extension cables to Motion Assist 360
drive cables
Fig. 6.12.1 Motion Assist 360 drive cables
6.12.1 Extension cable connections to Motion Assist
360 drive cables.
Extension cables connect Motion Assist 360 drive cables
in in-ground container o Motion Assist 360 control unit in
remote enclosure.
6.12.2 Connect Motion Assist 360 Hall sensor cable to
Hall sensor extension cable.
1. Insert Hall sensor cable (6) plug into Hall sensor
extension cable receptacle.
NOTICE
Insure plug is fully inserted and locked in
receptacle.
• Use container cable tie to secure cable; loop
and tie wrap excess cable as required.
• Cable must not be in contact with Motion
Assist 360 drive!
1
RX6016-001
Motor extension cable, 25' (standard)
Optional motor extension cables
RX6016-002
Motor extension cable, 50'
RX6016-003
Motor extension cable, 100'
2
RX6015-001
Hall sensor extension cable, 25' (standard)
Optional Hall sensor extension cables
RX6015-002
Hall sensor extension cable, 50'
RX6015-003
Hall sensor extension cable, 100'
3
RX6010
Motion Assist 360 drive
4
RC6060
Mounting plate
5
RX6005
Motor cable (21)
6
RX6006
Hall sensor cable (22)
Table 6.12.1
Motion Assist 360 drive and extension
cables
Fig. 6.12.2 Motor extension cable
Plug
Socket
1
12” ground wire
12” ground wire
Socket
Plug
2
Fig. 6.12.3 Hall sensor extension cable
3
4
6
5
Shield
Choke
6.12.3 Connect Motion Assist 360 power cable to drive
extension cable.
1. Insert power cable (5) plug into Drive Unit motor
receptacle (9) on control unit.
NOTICE
Insure plug is fully inserted and locked in
receptacle.
• Use container cable tie to secure cable; loop
and tie wrap excess cable as required.
• Cable must not be in contact with Motion
Assist 360 drive!