28
Crane 4000LE
07-2022
RL6002-003
Chapter 7
Crane 4000LE Wiring, Setup and Troubleshooting Manual
In-ground Motion Assist 360 drive and speed control
Remote control enclosure
Ref.
#
Cable
Wires
1 1/2" DC liquid tight flexible conduit
2
Mode switch**
6 conductor 18 AWG cable
3.1
Emergency Stop
(interior)
2 Conductor 18 AWG cable
3.2
Emergency Stop
(exterior)
2 Conductor 18 AWG cable
4.1
Wave to Open**
Push to Start
(interior) (option)
4 Conductor 18 AWG cable
4.2
Wave to Open**
Push to Start
(exterior) (option)
4 Conductor 18 AWG cable
5.1
Night bank
(interior) (option)
2 conductor 18 AWG cable
5.2
Night bank
(exterior) (option)
2 conductor 18 AWG cable
6
Fault LED
2 conductor 18 AWG cable
7
Service panel**
(option)
3 conductor 18 AWG cable
**Panel location may be adjacent to door.
7.1 Operator
interface
wiring
7 Wiring interfaces to Motion Assist 360
remote enclosure
Fig. 7.1.1
Door operator interfaces, interior
TIPS AND RECOMMENDATIONS
Reference Chapter 9 for wiring interface
diagrams:
• Motion Assist 360 power supply and control
unit located in remote enclosure.
2
6
7
3.1
4.1
4.1
Fig. 7.1.2 Door operator interfaces, exterior
3.2
4.2
4.2
Table 7.1.1 Operator interface wiring