40
Crane 4000LE
07-2022
RL6002-003
Chapter 9
Crane 4000LE Wiring, Setup and Troubleshooting Manual
In-ground Motion Assist 360 drive and speed control
Remote control enclosure
9.8 Service panel (option) installation and wiring
Fig. 9.8.1 Service panel
Fig. 9.8.2 Control unit Service COM 2
Fig. 9.8.3
DX4662 RJ45 handheld communication cable
9.8.1 Service panel installation.
1. Locate and install Service panel.
• Note cutout required for panel RJ45 port circuit
board.
• Fastener supplied is for installation to metal surface.
TIPS AND RECOMMENDATIONS
Service cable length: 20 feet.
9.8.2 Service
panel
wiring.
1. Route RJ45 cable (Fig. 9.8.3) from Service panel to
Motion Assist 360 control unit (Ref. Para. 7.2) in
Remote enclosure.
2. Plug RJ45 connector into Motion Assist 360 control
unit COM 2 connector.
NOTICE
Always use dormakaba handheld interface cable
DX4662!
Never use conventional network cable with
RJ 45 plug!
May cause permanent damage to handheld!
1
4
1
3
5
4
COM 2
Part / Assembly
Description
1
DX4662-001
Communication cable, 90 deg., RJ45, 3'
(Standard)
2
DX4662-002
Communication cable, 90 deg., RJ45, 10'
3
DX4662-003
Communication cable, 90 deg., RJ45, 20'
Table 9.8.2 DX4662 Communication cables
Part / Assembly
Description
1
DX4604-08C
Service panel, RJ45
3
RJ45 cover
4
RJ45
5
6-32 x 5/8" undercut flat head machine
screw
Table 9.8.1 Service panel