16
ED100LE
02-2021
DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapter 7
Axle extension
ED100LE
A
B
C
D
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Standard
●
1 7/32
31
2 15/16
75
7/8
22
2 19/32
66
3/4"
[20]
●
2
51
3 3/4
95
1 21/32
42
3 3/8
86
2 3/8"
[60]
●
3 9/16
91
5 5/16
135
3 7/32
82
4 31/32
126
Fig. 7.1.2 Assembly on hinge side, pull version with slide channel CPD and 1" [50] pivot pin
B
D
A
C
Upper edge door
Upper edge door
Space for cable feed
5 7/8”
[150]
4 3/16”
[106]
1 3/4”
[45]
1 1/4”
[32]
3 15/16”
[100]
2 1/2” [6
3]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
1 3/4”
[45]
Ø 1/4”
[6,6]
17 3/4”
[451]
1/8” [
3]
1 3
/4
”
[4
4]
When CPD lever is used, about 1 3/16” [30]
must be deducted from the actual reveal
depth when the parameter is set.
Reveal depth maximum 2 3/8” [60]
7 11/16”