"D" door width,
inches [mm]
"W" door weight, pounds [kg]
100 [45.4]
125 [56.7]
150 [68]
175 [79.4]
200 [90.7]
30 [762]
3.0
3.0
3.0
3.0
3.5
36 [914]
3.0 s
3.5 s
3.5 s
3.0 s
3.0 s
Minimum opening time to back check or 80 degrees (whichever occurs first).
Minimum closing time from 90 degrees to latch check or 10 degrees (whichever occurs
first).
12.1.2 A156.19, Table I: Minimum opening and closing times.
12.1.3 A156.19, Table II: Total opening time to 90 degrees.
Back check at 60°
Back check at 70°
Back check at 80°
Table I plus 2 s
Table I plus 1.5 s
Table I plus 1 s
If door opens more than 90°, it shall continue at the same rate as backcheck speed.
Back check occurring at a point between positions shall use lowest setting.
12.1.4 Other door weights and widths.
Closing time T = (D
W
)/188
D = Width of door in inches.
W = Weight of door in pounds.
T = Closing time to latch check in seconds.
SI (metric) units
Closing time T = (D
W
)/2260
D = Width of door in mm.
W = Weight of door in kg.
T = Closing time to latch check in seconds.
13 Install door signage, low energy door
13.1 Install door signage
13.1.1 Install door signage.
Install applicable door signage as outlined in Chapter 5,
ED100LE door signage.
14 Cover, end caps and spindle caps
14.1 Cover end cap and spindle installation
14.1.1 Cover and end cap installation.
Cover and end caps will be installed after ED100LE
operator setup is completed.
• Reference ED50LE/ED100LE Setup Manual.