49
ED100LE
02-2021
DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapter 18
1
Backplate, ED
operator
companion
DC3468-050
2
Companion closer
adapter
DC3468-070
3
#4 x 1/4-20 x 5/8"
Philips flat head
screw
DF0399-00G
4
1/4-20 x 1" Philips
FHMS undercut
DF3101-01Z
5
Door closer, 8816
08210970
Fig. 18.2.3 Closer adapter and closer assembly mounting to backplate – pull arm application
18.2.1 Install 8816 closer for pull arm application.
NOTICE
Verify closer spring size prior to installation.
NOTICE
PULL (T) mounting holes.
For pull arm application, use
PULL (T) mounting holes (Fig..18.2.3)
18.2 Install 8816 closer on backplate – pull arm mounting
3
#4 x 1/4-20 x 5/8"
Philips flat head
screw
DF0399-00G
(8) 4
Fig. 18.2.1 Companion screw kit
HK4607-001
(4) 3
Fig. 18.2.2 Companion closer
adapter fasteners
4
1/4-20 x 1" Philips
FHMS undercut
DF3101-01Z
1
2
3
PULL (T)
(4)
4
(4)
5
PUSH (J)
PULL (T)
Fig. 18.2.4 Closer adapter and closer assembled to backplate
PUSH (J)