53
ED100LE
02-2021
DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapter 19
19.1.1 8816 closer adjustments.
CAUTION
Confirm closer spring size prior to making any
closer speed adjustments.
CAUTION
Do not back valves out beyond closer casting.
19.1 8816 door closer adjustments
CAUTION
Maximum door opening angle: 1100.
CAUTION
Door should close in 3 to 6 seconds from 900.
NOTICE
Closer supplied with a size 2 spring setting.
6
Increase
Decrease
Fig. 19.1.2 8816 spring force adjustment
6
Spring force adjustment
Fig. 19.1.3 8816 closer adjustments
1
Sweep
2
Latch
3
Backcheck
positioning
4
Delayed action
5
Backcheck
19 8816 closer adjustments
1
2
4
3
5
Fig. 19.1.1 8816 closer adjustments
Latch
7°
Sweep
70°
75°
110°
Backcheck
Delayed
action
19.1.2 Sweep speed (1) adjustment.
Adjust sweep speed from 700 to 100.
• Increase speed: Turn sweep valve CCW.
• Decrease speed: Turn sweep valve CW.
19.1.3 Latch speed (2)adjustment.
1. Adjust latch speed from 100 to 00
• Increase speed: Turn sweep valve CCW.
• Decrease speed: Turn sweep valve CW.
19.1.4 Backcheck (3) adjustment.
1. Adjust backcheck for door area from 1100 to 700.
• Increase resistance: Turn valve CW.
• Decrease resistance: Turn valve CCW.
19.1.5 Backcheck positioning (5)adjustment.
Adjusting backcheck positioning will advance
approximately 150 in the "ON" position. Shipped from
factory fully "ON".
Backcheck positioning MUST be turned ON for arm and
track applications.
• Turn OFF: Turn valve CCW.
• Turn ON: Rotate valve CW.
19.1.6 Delayed action (4)adjustment.
1. Adjust delayed action for door area from 1100 to 750.
• Increase delayed action: Turn valve CCW.