9
ED100LE
02-2021
DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapters 2 and 3
3 Technical data
Maximum wire size
Connector plug
screw size
16 AWG
1/16”
Door
status
X7
97,98,99
Sr
parameter
Door closed
Door open
Door closed, locked
Com, N.O., N.C.
contacts
3.1 ED100LE operator technical data
3.1.1 Operating conditions.
Ambient temperature
5 to 122 °F
[-15 to 50⁰ C]
Suitable for dry
rooms only
Relative air humidity:
93% maximum, non-condensing
Power supply
115 Vac ±10%, 50/60 Hz
6.6 A maximum
Branch circuit
protection (provided
by others)
15 A maximum,
dedicated branch circuit
Protection class
NEMA 1 [IP20]
Power wiring:
black, white, bare
copper (ground)
12 AWG
maximum
Operating noise
Maximum 50 db(A)
3.1.2 General specifications.
Operator dimensions
(W x H x D)
27" x 2 3/4 x 5 1/8" [685 x 70 x 130 mm]
27" cover standard
Operator weight
21.8 lb [9.9 kg]
Power supply for
accessories
24 Vdc ± 5%, 1.5 A
Maximum door
opening angle
95 to 110° depending on installation type
3.1.3 Inputs
Wire size
Connector plug
screw size
14 AWG
1/16”
Activation
inputs
X4*
Interior, exterior
N. O. contact
Safety
sensors
X5
Swing, approach sides.
Night-bank
(intercom
system)
X10
57,
57a
8-24 Vdc/Vac +5%
Night-bank
(key switch)
X1
35, 3
d2
parameter
Configure for N.O.
or N.C. contact
Deactivation
of drive
function
X6
4, 4a
d1
parameter
Configure for N.O.
or N.C. contact
3.1.4 Outputs
TIPS AND RECOMMENDATIONS
• *
X4
terminal board numbers, reference
Chapter 4.
3
Fig. 2.11.2 Connect cable
2.11 Double door ED100LE operator connection cables
Fig. 2.11.1 Communication (sync) cable
Communication cable
Length
Item #
Quantity
HX3485-030
80"
[2030 mm]
1
1
Optional
HX3485-010
9 7/8"
[250 mm]
1
0
HX3485-020
40 1/2"
[1030 mm]
1
0
1
Connect cable
Length
Item #
Quantity
HX3484-030
119 5/8"
[3400 mm]
3
1
Optional
HX3484-010
68 7/8"
[1750 mm]
3
0
HX3484-020
94 1/2"
[2400 mm]
3
0
Technical data continued on page 10.