110
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Appendix B
Red LED status
Display
Description
Steady flashing
Control unit has detected error,
emergency mode activated.
On steady
ln 11
Hold-open device triggered.
Flashing 2 times
E 02
Locking device error.
Flashing 4 times
E 04
Safety sensor test error.
Flashing 5 times
E 25
SVP PR DCW module test negative.
Flashing 5 times
E 51
E 52
E 53
Incremental encoder error.
Flashing 6 times
E 62
Double door operation, 2nd system
has incompatible firmware version.
Flashing 6 times
E 63
Double door operation, 2nd system
has incompatible fire protection
setting.
Flashing 7 times
E 71
System error 1 (test), second
shutdown option.
Flashing 7 times
E 72
System error 2 (test), current
measuring circuit.
Flashing 7 times
E 73
System error 3 (test), braking circuit
Flashing 12 times
E 12
EEPROM error
Flashing 13 times
E 13
Motor overcurrent
Flashing 15 times
E 15
Faulty learning cycle
B.2.1 Red LED status codes.
B.2 Red LED status codes