63
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 29
29.6.1 Configuration parameters, detail
Parameter and value
range, factory setting
=
bold
.
Parameter description
1
0 - 4
0
Installation type
0
• Pull arm with track, wall
mounting on swing (hinge) side
• Pull arm and CPD lever with
track, wall mounting on swing
(hinge) side
1
• Standard push arm,
wall mounting on approach
(non-hinge) side
2
• Push arm with track, wall
mounting on approach
(non-hinge) side.
• Application specific
3
• Overhead concealed (OHC),
right hand (v2.1)
4
• OHC, left hand (v2.1)
2
Reveal depth
ED50
0
Reveal is set in increments of
10 mm (3/8"), "3" = 30 mm (1 1/8").
• Overhead concealed header:
Factory setting
3
Tb
ED50
9 to 12
10
Door width
10
Door width is set in increments of
100 mm (4"), "10" = 1000 mm
(39.4").
Reference Para. 29.2, measure
door width.
4
0 to 4
0
Door type
0
Single door
1
Double door
• Overlapping door (with
astragal)
• Active door operator.
2
Double door
• Overlapping door (with
astragal)
• Passive door operator.
3
Double door
• Edgeless door (no astragal)
• Active door operator.
4
Double door
• Edgeless door (no astragal)
• Passive door operator.
Fig. 29.6.1 LH outswing
Fig. 29.6.2 RH outswing
Header cover
Header cover
Header cover
Fig. 29.6.3 LH inswing
Header cover
Fig. 29.6.4 RH inswing
Bold numbers;
factory setting
29.6 ED50 OHC configuration parameters