91
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 35
35.1 Connect accessory wiring, single door
35 Connect accessory wiring
35.1.1 Connect accessory wiring.
TIPS AND RECOMMENDATIONS
• Reference Chapter 11, System
Accessories for terminal board
interfaces.
1. Terminate all accessory wiring at
ED50 low voltage terminal board in
header.
2. Secure all accessory wiring.
Fig. 35.1.1 Accessory wiring terminal board, ED50 operator on left example
35.2 Connect accessory wiring, double doors
35.2.1 Connect accessory wiring.
TIPS AND RECOMMENDATIONS
• Reference Chapter 11, System
Accessories for terminal board
interfaces.
1. Secure all accessory wiring in header.
35.1.2 Panic breakout switch wiring.
Reference Para. 17.6 for switch installation
on inswing doors.
1. Breakout switch wires terminate at X6-4
and 4a on ED50 terminal board.
Remove
jumper between 4 and 4a
(Fig. 35.1.2)
.
• Reference Para. 11.3, ED50 terminal
board interface.
35.1.3 Test system accessories.
Test functionality of all accessories.
Fig. 35.2.1 Low voltage terminal board modules, double door
1
LH ED50 controller
2
Low voltage
terminal board
module
3
RH ED50 controller
1
2
2
3
1
Low voltage
terminal board
module
1
Fig. 35.1.2 Terminals 4 and 4a
4, 4a
Jumper
35.2.2 Panic breakout switch wiring.
Reference Para. 35.1.1 for wiring.
35.2.3 Test system accessories.
Test functionality of all accessories.