27
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 13
13.3 Safety information labels, automatic swing doors
SAFETY
INFORMATION
Low Energy Swinging
Doors
1. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4. Inspect the floor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
traffic path clear.
5. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6. Have door inspected by an
AAADM certified inspector
at least annually.
AAADM
American Association of Automatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualified automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks,
in addition to those in the
Owner’s Manual, should be
made each day and after any
loss of electrical power
.
13.3.1 Low energy swinging door safety information
label
This AAADM label (Fig. 13.9.4) outlines safety checks
that should be performed daily on automatic swing
door controlled by an ED50 overhead concealed
operator configured for low energy operation.
13.3.2 Safety information label location
Place label in a protected, visible location on door frame,
near program switch panel if possible.
13.3.3 Annual compliance section of label
This section of label is only completed on low energy
swing doors that comply with ANSI/BHMA A156.19
standard and pass inspection by an AAADM certified
dormakaba USA Inc. technician.
13.3.4 Additional annual compliance inspection labels
Place additional labels over annual compliance
inspection section of safety information label.
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE: ______________
by AAADM Certified
Inspector
Number: ___________
13.3.5 Safety information label
Fig. 13.3.1 Annual compliance label, low energy
Fig. 13.3.2 Low energy