28
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 14
14 ED50 OHC installation template
14.1 Header installation
Fig. 14.1.1 Single door LH outswing header
H
3 3/4”
CL
Spindle
H
G
G
Width between jambs = header width + 2 x end cap thickness (.08” each)
End Cap
End Cap
Fig. 14.1.2 Section view G-G
1
Jamb bracket
1.1
Jamb bracket
mounting holes, 9/32"
dia.
1
Jamb bracket
mounting holes,
9/32" dia.
For 1/4-20 fastener.
Fig. 14.1.2 Section view H-H
2
Header fastener
3
Jamb cutout for wiring
4
Jamb bracket cutout
for wiring
2
Jamb cutout for
wiring
2 3/4”
3/4”
2 1/2”
3/4”
3/4”
1 1/4”
H-H
Scale 1: 2
ø
1 3/8”
Jamb
header
cover side
1
1
1
1
2
1 1/16”
Jamb
6”
4”
1
1.1
2
3
4
4 1/2”
G-G
Scale 1: 2
2 5/8”
1 3/8”
Jamb