59
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 29
29 System setup for single door installation
1
2
29.1 Set braking circuit plug position
Fig. 29.1.1 Braking circuit socket and plug views
1
Braking circuit plug
2
Braking circuit 3 pin
socket
3
User interface
5
Power fail closing
speed potentiometer
Fig. 29.1.2 Plug position, outswing
Fig.29.1.3 Plug position, inswing
1
Braking circuit plug
2
Braking circuit
3 pin socket
5
Power fail closing
speed potentiometer
1
Braking circuit plug
2
Braking circuit
3 pin socket
5
Power fail closing
speed potentiometer
29.1.1 Set braking circuit plug position.
• Operator braking circuit plug is
positioned in its 3 pin socket for an
outswing or inswing installation.
• Braking circuit plug is factory installed in
the two pins away from user interface,
the outswing position.
(Fig. 29.1.1 and Fig. 29.1.2
).
WARNING
Braking circuit will not work correctly
if braking circuit plug is improperly
positioned, or if an incorrect plug is
used!
Door may close at high speed
and/or be difficult to open!
WARNING
Power switch (Fig. 29.1.4) must be
OFF before changing plug position!
1
2
Fig. 29.1.5 LH outswing
Fig. 29.1.6 RH outswing
Header cover
Header cover
Header cover
Fig. 29.1.7 LH inswing
Header cover
Fig. 29.1.8 RH inswing
29.1.2 Door pivot arm configurations
3
Power switch
4
115 Vac module
Fig.29.1.4 115 Vac power switch
3
4
2
1
3
5
2
1
3
5
5
5