75
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 31
31 System setup for double door installation
1
2
31.1 Set braking circuit plug position for each ED50 operator
Fig. 31.1.1 Braking circuit socket and plug views
1
Braking circuit plug
2
Braking circuit 3 pin
socket
3
User interface
5
Power fail closing
speed potentiometer
Fig. 31.1.2 Plug position, outswing
Fig.31.1.3 Plug position, inswing
1
Braking circuit plug
2
Braking circuit
3 pin socket
5
Power fail closing
speed potentiometer
1
Braking circuit plug
2
Braking circuit
3 pin socket
5
Power fail closing
speed potentiometer
31.1.1 Set braking circuit plug position for
each ED50 operator plated on door
configuration.
• Plug is positioned in its 3 pin socket for
an outswing or inswing installation.
• Braking circuit plug is factory installed in
the two socket pins away from user
interface, the outswing position.
(Fig. 31.1.1 and Fig. 31.1.2
).
WARNING
Braking circuit will not work correctly
if braking circuit plug is improperly
positioned, or if an incorrect plug is
used!
Door may close at high speed
and/or be difficult to open!
WARNING
Power switch (Fig. 31.1.4) must be
OFF before changing plug position!
1
2
Fig. 31.1.5 Outswing
Fig. 31.1.6 LH double egress
Fig. 31.1.7 Inswing
Fig. 31.1.8 RH double egress
31.1.2 Double Door pivot arm configurations.
3
Power switch
4
115 Vac module
Fig.31.1.4 115 Vac power switch
3
4
2
1
3
5
2
1
3
5
5
5