80
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 31
Step 1
Press
Press and hold PRG button greater
than 3 seconds to enter program
mode,
AS
parameter is displayed.
If no change required, go to step 7.
Step 2
Press
Displays "00" , factory setting.
Step 3
Press
"00" starts flashing.
Step 4
Press
Scroll to select parameter value.
"4", OHC LH shown as example.
Step 5
Press
Saves value entered. Display stops
flashing.
Step 6
Press
Returns to Installation type parameter.
31.7.1 Set parameter AS, installation type for each
ED50 operator.
Reference Para. 31.1.2 for door configurations.
31.7 Set configuration parameters; double door
Step 7
Press
Scroll to
Tb
parameter.
Step 8
Press
Displays "10" , factory setting.
Step 9
Press
"10" starts flashing.
Step 10
Press
Scroll to select parameter value.
"9" shown as example.
Step 11
Press
Saves value entered.
Display stops flashing.
Step 12
Press
Returns to door width parameter.
Exit program mode.
(Step 13).
Step 13
Press
Exit program mode. Display indicates
"ready for learning cycle".
31.7.2 Set parameter Tb, door width for each ED50
operator.
31.7.3 Parameter dL, door type.
TIPS AND RECOMMENDATIONS
Reference Chapter 30 for door width
parameter values.
TIPS AND RECOMMENDATIONS
Parameter
dL
factory setting is 0, single door.
Single door parameter will be used for each
operator during initial ED50 startup.
Installation type
Parameter
value
Parameter description
0*
Pull arm with track, wall mounting on swing
(hinge) side.
1
Push arm, wall mounting on approach (opposite
hinge) side.
2
Push arm with track, wall mounting on approach
(opposite hinge) side.
3
Overhead concealed (OHC) RH: Ref. Para. 33.2
4
OHC LH: Ref Para. 33.2
*
Factory setting