99
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Appendix A
Configuration
Parameters
Description
1
AS
Installation type
2
rd
Reveal depth
3
Tb
Door width
4
dL
Door type
Driving parameters
Description
5
So
Opening speed, automatic mode
6
Sc
Closing speed, automatic mode
7
dd
Hold open time, automatic mode
8
dn
Hold open time, night/bank
9
do
Hold open time, manual opening of door
10
Sb
Wall masking on door swing (hinge) side
11
ST
Safety sensor test
12
SA
Activation by safety sensor on approach
(opposite hinge) side
13
SP
Suppression of safety sensor on swing
hinge) side during initial movement (v1.9)
14
Ud
Locking mechanism delayed opening time
15
Pu
Door preload prior to unlocking
16
TS
PR (Power reserve) module test
17
Fo
Static force on door closing edge in
opening direction (wind load control)
18
Fc
Static force on door closing edge in
closing direction (wind load control)
19
EP
Motor driven latching action, automatic
mode
20
EA
Door opening angle at which motor
driven latching action is activated
21
FH
Keep closed force
22
PG
Push and Go
23
PS
Program switch type
24
S1
DCW EPS, electronic program switch
behavior following a power reset
25
S2
Internal program switch; switch
function on delay
26
du
Door unlocking during business hours
27
Sr
Status relay function, terminal block X7
Driving parameters
Description
28
bE
Input 4/4a and X3, 1G 24V locking
device output configuration
29
CC
Cycle counter, number displayed * 10000
30
EC
Delete error log
31
CS
Reset service interval display (yellow LED)
32
SL
Factory setting level (Fact Setup button)
33
OA
Opening angle, set during learning cycle
34
hd
Door closer mode, automatic or manual
35
hA
Power assist function activation angle
36
hF
Power assist function force adjustment
37
hS
Power assist function support for manual
mode in door closed position (v1.9)
38
F1
Upgrade card, fire protection
39
F2
This paragraph left intentionally blank.
40
F3
Professional upgrade card, flip flop
function, night/bank
41
F4
Professional upgrade card, extended
hold open time
42
F5
Professional upgrade card, nurse-bed
function (double doors only)
43
F7
Upgrade card, barrier free toilet
44
F8
Upgrade card, DCW I/O module
45
C1
Configuration of COM 1 interface
46
bc
Back check angle when door opened
manually
47
Td
Door thickness [mm]
48
d1
Deactivation of drive, emergency
pushbutton at X4, 4 and 4a, trigger type
(v1.7)
49
d2
Night/bank function, trigger type (v1.7)
50
FC
Hold open system release by manually
closing door, trigger type (v1.7)
51
Ad
Active door with astragal: caster angle,
angle door must reach before passive
door starts to open
52
HS
Hinge clearance
53
S3
OHC mode; permanent open via
night-bank input (v2.1)
54
S4
OHC mode; manual force overload drive
release (v2.1)
A1.2 Parameters