20
ED50LE
09-2021
DL4616-002
dormakaba ED50LE operator – Fine cover
Installation Instructions
Chapter 8
8 ED50LE operator installation
8.1 Installation preparation
NOTICE
Installation steps listed in Chapter 8 through 11
are a recommendation. Structural, local
conditions, available tools, or other factors or
circumstances may require modification to
these steps.
WARNING
ED50LE system should be installed by trained
and knowledgeable installers experienced in
installation and commissioning of swing door
operators.
The installer should be familiar with all
applicable local and national building code
requirements, and with requirements of
current ANSI/BHMA standard A156.19, Power
Assist and Low Energy Power Operated
Doors.
8.1.1 Door frame and door.
CAUTION
Insure area around door frame, adjacent walls
and door is readily accessible and free of
objects and debris.
8.1.2 Knowing act devices.
1. Verify knowing act devices planned for or in place for
the door.
TIPS AND RECOMMENDATIONS
Knowing act device wiring should be planned
for prior to operator installation.
8.1.3 ED50LE mounting plate installation preparation.
CAUTION
Using applicable ED50LE installation template
(Chapter 7), holes for mounting plate
fasteners must be located and drilled into door
frame, wall or substructure prior to mounting
plate installation.
CAUTION
Mounting plate installation must be orientated
with 115 Vac connection towards door hinge side.
8.1.4 ED50LE mounting plate extension used with
optional full door width cover.
TIPS AND RECOMMENDATIONS
Mounting plate extension is included
for full width cover installation.
• Reference Appendix A for mounting
plate extension and full width
cover installation.
8.1.5 ED50LE 115 Vac electrical installation.
WARNING
Work on electrical equipment and 115 Vac
wiring installation must be performed only by
qualified personnel
!
WARNING
115 Vac wiring to ED50LE operator must
conform to local and national electrical codes.
NOTICE
Double door Installation:
Repeat steps in Chapter 8 for each ED50LE
operator
TIPS AND RECOMMENDATIONS
ED50LE installation.
The ED50LE must be installed on an interior
door.