5
ED50LE
09-2021
DL4616-002
dormakaba ED50LE operator – Fine cover
Installation Instructions
Chapter 2
2 Product overview
11
Terminals for
accessory wiring
12
Bag containing
terminals and third
guide pin*
13
Guide pin
* Included with operator
Fig. 2.1.2 Accessory terminals, guide pin
12
11
13
Fig. 2.1.3 ED50LE backplate plate screw kit
HK4053-010
1
#12 x 2 1/2" Phillips
FHWS
DF0670 000
2
1/4-20 x 1 1/2"
PFHMS
DF0671-000
Fig. 2.1.4 Decal kit, low energy HK3137-0X0
1
DD0586-010
2
DD0758-010
3
DD0762-010
4
DD0762-020
8
Safety Information
label, low energy
DD1269-040
9
Label, Service Call
DD3425-010
Assembly #
Item #
Quantity
HK3137-010
Single door
decal kit
1
2
2
1
3
1
4
1
8
1
9
1
Assembly #
Item #
Quantity
HK3137-030
Double door
decal kit
1
4
2
4
3
2
4
2
8
1
9
1
SAFETY
INFORMATION
Low Energy Swinging
Doors
1. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4. Inspect the floor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
traffic path clear.
5. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6. Have door inspected by an
AAADM certified inspector
at least annually.
AAADM
American Association of Automatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualified automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks,
in addition to those in the
Owner’s Manual, should be
made each day and after any
loss of electrical power .
1
3
4
2
8
DD0758-010
ACTIVATE SWITC
H
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
9
Assembly #
Item #
Quantity
HK4953-010
Screw kit
1
12
2
12
1
2
2.1 ED50LE low energy operator
Fig. 2.1.1 ED50LE operator HX4680-010