104
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Appendix A
Parameter
Value
range
Units
Factory
setting Description
Reset service interval display,
operator yellow LED
31
0 - 1
0
0
No function.
1
1. When "1" entered:
• Service cycle counter is reset to 200,000.
• Service interval is reset to 12 months.
• Yellow LED not illuminated.
2. Parameter is then automatically reset to "0".
3. Values other than default values must be set using dormakaba USA, Inc.
handheld:
• Maintenance interval
• Maintenance cycles
Factory setting level
32
1 - 2
1
1
Parameter
SL
is used to determine what data will be reset during factory setting
process.
Standard factory settings
• Program switches CLOSE.
• Door closed.
• Press 4 button keypad down button
for greater than 8 s.
1. All parameters reset to factory settings.
2. Procedure completed when "8" on 2 digit displays blinks twice.
3. Installed upgrade cards remain valid and do not require reinstallation.
4. Learning cycle required.
2
Extended factory settings
• Program switches CLOSE.
• Door closed.
• Press 4 button keypad down button
for greater than 8 s.
1. All parameters reset to factory settings.
2. Procedure completed when "8" on 2 digit displays blinks twice.
3. Installed upgrade cards deleted from operator memory.
4. Parameter
SL
automatically reset to 1.
5. Control unit and upgrade cards can be used independently (delivery status).
6. Learning cycle required..
Opening angle
1. Door opening angle set during learning cycle is displayed.
2. Opening angle can only be changed during learning cycle.
3. Due to installation and parameter tolerances, display value may not match actual door
position.
33
0 - 110
°
A.1.1 Driving parameters detail.