30
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 12
12.2 ED900 operator installation with standard covers
12.4.1 ED900 active and inactive door assignments.
1. Position ED900 operators on a flat surface
orientated as shown in Fig. 12.5.1.
2. Determine ED900 active and inactive door
assignments.
TIPS AND RECOMMENDATIONS
Active and inactive door assignments.
Fig. 12.1.1 shows example of active and
inactive door assignments.
Door assignments may be reversed.
• Use
dL
door type parameter to assist in determining
ED900 active and inactive door assignments
TIPS AND RECOMMENDATIONS
dL door type parameter.
dL
parameter is set during double door
commissioning – Reference Chapter 24.
Door type
Parameter
value
Parameter description
0*
Single door
1
Double door with astragal.
• Active door operator – door opens first.
2
Double door with astragal.
• Inactive door operator.
3
Double door, without astragal.
• Active door operator.
Both doors open simultaneously.
4
Double door, without astragal.
• Inactive door operator.
Both doors open simultaneously.
*
Factory setting
Table 12.4.1 Door-type parameter dL.
12.4 ED900 operators – assign active door and inactive door type
Fig. 12.2.1 ED900 standard cover installation for double door operation
12.3 ED900 operator installation with full width cover (option)
Fig. 12.3.1 ED900 full width cover installation for double door operation
Power switch
Inactive door
Program switches
Power switch
Active door
Program switches
Single program switch
Power switch
Active door
Inactive door