49
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 15
15.2.1 Select installation template.
1. Select applicable installation template.
NOTICE
Installation templates: Reference Chapter 13.
15.2.2 Fasten mounting plates to jamb and/or wall.
CAUTION
Install shims between mounting plates and wall
as required.
CAUTION
ED900 conduit box (if used):
• Insure ED900 conduit box
(Para. 14.3) is prepared with applicable
conduit fitting or cord grip.
• Insure jamb or wall is prepared for wiring
to each ED900 conduit fitting or cord grip.
1. Using template as a guide, prepare
twelve mounting holes at first mounting plate
location for mounting plate fasteners (Fig. 15.2.1).
2. Install first plate.
3. Full width cover option: Using mounting plate
extension as a guide, mark four mounting holes for
extension.
4. Using template as a guide, prepare
twelve mounting holes at second mounting plate
location for mounting plate fasteners (Fig. 15.2.1).
5. Install second mounting plate.
6. Full width cover option: Install mounting plate
extension.
15.2.4 Mounting plate installation checks.
CAUTION
• Check level.
• Check spindle to hinge centerline distance.
• Check mounting plate alignment.
15.2.5 Install third guide pin.
1. Install third guide pin (Fig. 15.2.2) in each mounting
plate (Fig. 15.1.1).
• Use 3 mm hex T-handle or hex key.
13
Fig. 15.2.2 Guide pin
13
Guide pin
15.2 Install ED900 mounting plate to jamb and/or wall
CAUTION
Select fasteners based on door frame and wall
material.
CAUTION
Use fasteners provided with ED900 (Fig. 15.2.1).
Fig. 15.2.1 Mounting plate fasteners
15
1/4-20 x 1" FH
machine screw
16
No. 14 x 1 "FH wood
screw
(12)
15
(12)
16