76
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 23
Step 13
Press
Scroll to
Tb
parameter.
Step 14
Press
Displays "10" , factory setting.
Step 15
Press
"10" starts flashing.
Step 16
Press
Scroll to select parameter value.
"7" is example, for door widths of
28" to 31 15/16"
Step 17
Press
Saves value entered.
Display stops flashing.
Step 18
Press
Returns to door width parameter.
If single door, exit program mode
(Step 19).
Step 19
Press
Exits program mode. Display indicates
"ready for learning cycle".
23.2.3 Set parameter Tb, door width.
20.2.4 Parameter dL, door type.
Fig. 23.2.2 4 button keypad,
2 digit display
3
Four button
keypad
4
Two digit display
TIPS AND RECOMMENDATIONS
Reference Chapter 18 for door width
parameter values.
TIPS AND RECOMMENDATIONS
Parameter
dL
factory setting is 0, single door.
4
3
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s
LEARN
Fact-Setup
> 3s
> 8s
23.3 Set parameter PS, program switch type
23.3.1 Full width cover or Key switch panel option –
set parameter PS to 1.
Step 1
Press
Press and hold PRG > 3 s to enter
program mode, AS parameter
displayed.
Step 2
Press
Scroll to
PS
(Program switch type)
parameter.
Step 3
Press
Displays "00" , factory setting.
Step 4
Press
"00" starts flashing.
Step 5
Press
Scroll to select parameter value "1",
External mechanical program switch
connected to operator terminal board.
CAUTION
Key switch panel options – program switch
wired to ED900 terminal board.
Reference Appendix D.
Parameter
PS
(Program switch type) must be
set to 1.
Step 6
Press
Saves value entered. Display stops
flashing.
Step 7
Press
Returns to program switch parameter.
Step 8
Press
Exits program mode.