91
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Chapter 31
1. Insert first upgrade
card into upgrade
card slot.
2. This card will become
container module.
3. Yellow LED flashes
on and off once
during card insertion.
4. Green LED slowly
flashes on and off
indicating
communication
between card and
control module.
5. Upgrade card
becomes container
module, green LED
continues to slowly
flash on and off.
• Upgrade card function
is now available.
31.3 Installing upgrade cards
31.3.2 Installing first upgrade card.
31.3.1 Set program switch to CLOSE.
1
Set program switch to Close.
9
Horizontal bars indicate
controller in stand by
mode.
1
Upgrade card slot
3
Green LED
7
Container module
TIPS AND RECOMMENDATIONS
Container module can be configured
using applicable parameter (F1 - F8) for
card. Reference Chapter 22, Parameters.
1. Remove container
module from upgrade
card slot.
6
1
2. Insert next upgrade
card into upgrade
card slot.
4
6
• Card function is copied
to control module;
upgrade card is then
invalidated.
• Yellow LED indicates
procedure is complete.
6
1
3. Remove upgrade card
from upgrade card
slot.
4. Reinsert container
module into upgrade
card slot.
• Control unit recognizes
container module;
container module
stores new functions.
• Green LED slowly
flashes on and off
indicating successful
operation.
• New card functions
are now available.
31.3.3 Installing additional upgrade cards.
3
Green LED
7
Container module
TIPS AND RECOMMENDATIONS
New upgrade card can be configured
using applicable parameter (F1 - F8) for
card. Reference Chapter 22, Parameters.
1
Upgrade card slot
6
Next upgrade card
7
Container module
8
Program switch
9
2 digit display with
horizontal bars
8
1
2
4
Yellow LED
7
Container module
1
Upgrade card slot
2
First upgrade card
7
3
7
3
1
7
1
7
7
4