EML Header Shim
10
RTS88 adjustment
PT21 adjustment
2.3.1
Ensure RTS is plumb and level.
2.3.2
Adjust via slotted holes in angle bracket prior to
fully tightening screws.
2.3
RTS88 adjustments
Valve B
Valve A
•
Valve “A” - Closing/sweep speed - from maximum
opening to 0°.
Clockwise
- decrease closing speed
Counter-clockwise
- increase closing speed
•
Valve “B” - Latch speed - from maximum opening
to 20°.
Clockwise
- decrease closing speed
Counter-clockwise
- increase closing speed
Slotted
holes in
angle
bracket
2.4
PT21 adjustments
2.4.1
Ensure PT21 is plumb and level.
2.4.2 Raise pivot pin up completely by rotating pin
adjustment screw.
Pin
adjustment
screw
Pivot
Pin
2.4.3 Lower pin once door is properly in place.
*Unverisal: 5/8” [15]
**MUNDUS: 9/16” [14]
Fig. 5