dormakaba Header Installation Instructions with EML310/320 and 371/372
For use with DRS Rails and Patching Fittings (4-1/8”, 4-1/2”, 6” Headers)
933903
07-2019
EML Header Shim
4
Technical specifications
1.2
EML310/320 and EML371/372 Specifications Overview
1.1.1
General information
•
This product must be installed according to all
applicable building and life safety codes.
•
Due to the variety of mounting configurations
available with this product, a survey and
assessment of the physical area in which the
product will be installed must be performed.
•
This door frame must be inspected and deemed
structurally sound prior to installation of the
electromagnetic lock. The structural integrity of the
mounting surfaces must be strong enough to meet
or exceed the holding force of the product.
•
The product must be protected from potential
damage due to intruders or tampering.
•
The product should be installed in a location that
will not hinder or create a potential safety hazard
to authorized personnel accessing the protected
area.
•
Because electromagnetic locks are used in a variety
of applications and different door frame
configurations, an experienced installer with
knowledge of this product must make a
determination of the optimal mounting method for
this specific application.
•
The components, hardware, installation
instructions and mounting template included with
this product are intended for use on outswinging
doors.
•
Do not install this product on the exterior of a
building.
•
Do not use as a doorstop. This will void the
warranty.
•
Separate accessories not included with this
product must be used in the following applications:
»
Inswinging doors
»
Narrow head jamb situations or center-hung
doors
»
Wherever there is insufficient space on the
door frame header to mount the lock
»
Hollow metal or wood frames where the
door stop is not thick enough to allow the
product to be installed
»
Wherever an obstruction in the door
prevents installation of the armature plate
at the proper height
»
Doors that do not permit the armature plate
to be mounted low enough to meet the
magnet surface.
•
Installation of this product should be done by an
experienced installer with knowledge of this
product.
•
NOTE:
It is highly recommended that thread
locking compound be applied to all screws during
installation to reduce chance of screws loosening
over extended time.
1.1.2
Listings
•
These products have been successfully tested and
evaluated by UL in two separate categories for use
in both the United States and Canada.
•
Auxiliary Lock - The GWXT fire listing qualifies
these for use with UL Classified fire doors
maximum 4’ [1219] in width and 8’ [2438] in height
rated up to and including 1 hour.
•
Special Locking Arrangement Component -
Additionally, these products are qualified
components for the purpose of locking outward-
swinging exit doors against unauthorized egress.
They are designed to release automatically in case
of a power failure or upon activation of an
automatic fire alarm system wired to the power
supply fire panel relay.
1.1.3
Conditions of acceptability
•
This product is intended for use with Special
Locking Arrangements which are installed in
accordance with the manufacturer’s installation
and operation instructions, the Life Safety Code,
NFPA 101 of the National Fire Protection
Association, and the local authority having
jurisdiction.
•
The power for this unit is to be provided by a Listed
(ALVY, ALVY7, FULA, FULA7, FUPPC, UEHX7,
APHV or APHV7) Class 2 power supply when
designated as a Special Locking Arrangement
(FWAX or FWAX7).
•
The suitability of the lead wires is to be evaluated
per the requirements for the end-use product.
•
When this product is installed in conjunction with a
fire alarm control panel, the wiring from the control
unit to this product device shall be for fail-safe
operation.
•
For Canadian installations, this product is to be
installed in accordance with the manufacturer’s
installation and operation instructions, The
Canadian Electrical Code C22, 1-02, and the local
authority having jurisdiction.
•
To qualify for use in a delayed-egress locking
system, the relock delay must be set to 0 seconds.
•
UL testing was conducted on standard model
without accessories. These locks are not intended
or tested for use as a UL Listed Buglar Alarm
System Unit.
•
These models have also been independently tested
to the ANSI/BHMA A156.23-2010 American
National Standard for Electromechanical Locks.
•
Holding Force: 1500 lbf
•
Cycle Test: Grade 1 = 1 million cycles