Program switch settings:
Old New
OFF
1
2
3
4
5
AUTOMATIC
EXIT ONLY
PARTIAL
OPENING
PERMANENTLY
OPEN
Program switch settings:
Old New
OFF
1
2
3
4
5
AUTOMATIC
EXIT ONLY
PARTIAL
OPENING
PERMANENTLY
OPEN
AUTOMATIC FOLDING DOOR LOG BOOK
If a person or object comes within range of the
detectors or presence sensor, the door opens to the
preset partial opening width and closes at the end of
the preset hold-open time.
The opening width of the door can be adjusted
individually. To do this:
Close the door using the OFF switch setting
Set the program switch to PERMANENTLY OPEN
The door opens at low (check) speed
As soon as the door reaches the desired
partial opening width, set the program switch to
PARTIAL OPENING
The door stops and the control unit stores the
desired position
The door commences a closing cycle
The door opens in check speed to its full opening width
and remains in the position until another function is
selected.
In the event of power failure
If the program switch is in the AUTOMATIC
position, the door will fail open.
If the program switch is in the OFF position, the
door will remain closed To open the door, turn the
program switch to AUTOMATIC. After a short
delay the door will open at reduce speed and
remain open until power is restored or the
program switch is turned to Off.
Alternatively, if FIRST ENTRY - LAST EXIT is fitted,
operate button once or key once to open the door.
To close the door, operate either button or key
once.
This sequence can be carried out as required until
power is restored.