background image

 

 

 

             Page 9 

Clockwise turning of the large 
gear will retract the bolt pin. 

Anti-clockwise turning of the large 
gear will extend the bolt pin. 

The GL10 features multiple locking / unlocking to allow for misaligned gates or unforeseen problems. If the bolt pin 
meets an obstruction as it is trying to secure the gate, it stops and withdraws before attempting to lock again. It has 
a total of three attempts to secure the gate after which time it will sound an alarm. The same function is present when 
the GL10 unlocks. 

 
 
7.3 General 

 
If the batteries are fitted and the power is removed to the GL10 at any time during its operation, the lock will revert to 
its  pre-selected  state  of  either  unlocked  or  locked.  The  GL10  has  been  designed  to  operate  with 

high  quality 

disposable alkaline batteries

 and may not work correctly with alternatives. Should the batteries become flat the 

lock will sound an alarm to indicate a battery change is required.   
 
If  the  batteries  are  not  replaced  once  they  have  become  depleted,  the  GL10  will  automatically  revert  to  the  Fail 
Maintained state; i.e. in the event of a power failure the lock will stay in the position it was in before the power was 
removed. 
 
The three monitors can be used to provide door and bolt position information regardless of the locks configuration. 
 
Manual operation of the GL10 is available by removing the cover to allow access to the lock mechanism. The supplied 
key can be used to open and remove the cover and once access is available a screwdriver can be inserted into the 
centre of the large gear and turned to move the bolt pin in or out.     
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

7.4 Alarms 

 
To offer instant feedback about the locks state, the GL10 has an on board beeper which sounds at various times. 
The table below details the different alarms expected from the GL10.  
 
  

Locked confirm 

1 Short beep 

Unlocked confirm 

2 Short beeps 

Failure to lock / unlock 

5 Long beeps 

Battery replacement 

5 Short beeps sounded 5 seconds after a lock activation and repeated every 
10 minutes until the batteries are replaced 

Diagnostic 

Various beeps 

– used for service 

 
 
 
 

Summary of Contents for GL10

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Electronic Gate Lock GL10 ...

Page 2: ...kes position o Drill the strikes mounting holes o Secure the strike in position o Wire the lock o Cover the lock WIRING OPERATING CONFIGURATION o Fail State o Auto re lock o Timed re lock o Diagnostic mode OPERATION o Auto re lock ON o Auto re lock OFF o General o Alarms SPECIFICATIONS DIMENSIONS o Lock o Strike MAINTENANCE WARRANTY UPGRADE 2 2 2 2 3 4 4 4 4 4 5 5 5 5 6 6 7 7 7 7 7 8 8 9 9 10 10 1...

Page 3: ...two keys Lock Strike Also included in the box are 4 x AA batteries Because of the various fitting locations of the GL10 no mounting bolts are supplied The mounting holes in the lock and strike are 8 5mm slotted holes so accept M8 size bolts 3 PRE INSTALLATION ASSESMENT 3 1 Mechanical Before the lock can be installed consider its location and orientation The GL10 can be mounted horizontally or down...

Page 4: ...stems to provide full monitoring Once the number of wires and their destination is determined it needs to be decided how the wires will enter the lock They can either come in through a 20mm weather proof wiring gland at the rear of the lock not supplied or through a hole under the locks base which will ensure the wires can be hidden Finally the correct wire gauge needs to be chosen to ensure a min...

Page 5: ...Drill the lock mounting holes Use a M8 drill bit to drill the three mounting holes in the fence post Check on the preferred wiring method and if running the wires through the base is desired also mark and drill the wire hole now See section 5 Wiring 4 3 Secure the lock in position Push the bolts through the fence post and position the lock over the protruding bolt ends Place nuts on the three bolt...

Page 6: ...s Place nuts on the three bolts and tighten them to secure the strike to the gate 4 7 Wire the lock Using a screwdriver and following the connection guide on the printed circuit board connect the required wires to the lock Detailed wiring information can be found in section 5 Wiring 4 8 Cover the lock Position the cover over the lock and push it down and forward Use the keyed cam lock in the back ...

Page 7: ...O Door Position Switch Normally open contact of the gate position monitor C Common contact of the gate position monitor There are two options available when running wires into the GL10 they can be brought in through a 20mm wiring gland not supplied in the rear of the cover or run discreetly through the hole in the locks base Running wires out of the lock via the hole in base ensures a more weather...

Page 8: ...e the gates position and automatically lock when it is closed is paramount to increasing security as it eliminates the need for the user to do so If Auto re lock is not selected the GL10 operates on a toggle method In this configuration an activation of the control signal will cause the GL10 to unlock and a second activation will cause it to lock assuming the strike is in place 6 3 Timed re lock S...

Page 9: ...NO GATE CLOSES HAS THE GATE OPENED UNLOCK SIGNAL HAS THE BOLT PIN RETRACTED AFTER 3 ATTEMPTS GL10 IN STANDBY GATE IS UNLOCKED GL10 IN STANDBY GATE IS LOCKED HAS THE BOLT PIN EXTENDED AFTER 3 ATTEMPTS HAS A LOCK SIGNAL BEEN SENT YES YES NO NO YES NO YES NO YES NO GATE CLOSES INTERNAL ALARM SOUNDS HAS THE BOLT PIN EXTENDED AFTER 3 ATTEMPTS IS THE GATE OPEN HAS THE GATE OPENED WITHIN 1 MINUTE UNLOCK ...

Page 10: ...uired If the batteries are not replaced once they have become depleted the GL10 will automatically revert to the Fail Maintained state i e in the event of a power failure the lock will stay in the position it was in before the power was removed The three monitors can be used to provide door and bolt position information regardless of the locks configuration Manual operation of the GL10 is availabl...

Page 11: ...s free to operate as normal 8 SPECIFICATIONS Bolt Pin Stainless Steel ø18mm 35mm stroke Lock Die Cast Aluminium 152mm x 88mm x 78mm Strike Die Cast Aluminium 75mm x 75mm x 70mm Holding Force 3000Kg 30000N Power Supply 12 24VDC 15 Durability 1 000 000 Operations Current Usage Holding 12V 15mA Operation 12V 300mA Stall 12V 2A 24V 15mA 24V 200mA 24V 1A Batteries 4 x AA 1 5VDC Alkaline Monitor Switche...

Page 12: ...nty against faulty or malfunctioning parts components or product At the manufacturer s discretion either a replacement lock or affected part will be supplied to remedy the fault Mistreatment or ill use of the lock may void the warranty dormakaba will not be liable for any direct indirect incidental or consequential loss or damage in any way related to this product 12 UPGRADE dormakaba reserves the...

Reviews: